EUVIMEDEUVIMED entdecken
Open Access

The effect of different work rate increasing rates on cardiopulmonary exercise testing in arm ergometer

Zeng-Fei Zhang, Xing-Guo Sun, Jia-Hao Chen, Fan Xu, Meng-Jun Xiang, Jiang Huang, Ben Xie, Chao Shi, Yan-Fang Zhang, Fang Liu, Lin Li, You-Hong Xie

Journal of Thoracic Disease · 2025-09 · 17 (9) · 7124-7140

DOI: 10.21037/jtd-24-531 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Thoracic Disease, 2025-09. Verfasst von Zeng-Fei Zhang und 11 weiteren Autor:innen. Beteiligte Einrichtung: Department of Rehabilitation Medicine, The Affiliated Rehabilitation Hospital of Chongqing Medical University, Chongqing, China. Die Arbeit wurde bisher 2-mal zitiert (Crossref). Der Volltext ist frei in PubMed Central verfügbar.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Cycle ergometer is commonly used for cardiopulmonary exercise testing (CPET), which is the objective and quantitative golden standard for functional evaluation and training, while arm CPET is less commonly used to clinically assess a patient's overall functioning. To determine optimal CPET protocols, we studied the effect of different work rate increasing rates of arm ergometer on CPET key variables.

Methods

We recruited fourteen non-symptomatic participants without any clinical diagnosis, and first performed maximal leg CPET for functional evaluation, followed by four maximal arm ergometer CPETs using different work rate increasing rates (5, 20, 35, and 50 W/min) in random order on various days in one week (7 days). The key variables are oxygen uptake ( V ˙ C O 2 ), heart rate (HR), minute ventilation ( V ˙ E ), tidal volume (VT), breathing frequency (Bf), anaerobic threshold (AT), work rate, incremental exercise time (Tlim), respiratory exchange ratio (RER). One-way analysis of variance (ANOVA) with Tukey's post-hoc test compared outcomes across the four increasing rate protocols, and a paired t-test assessed arm vs. leg differences.

Results

All participants safely finished maximal CPET using leg and arm ergometers, and they had normal leg CPET peak V ˙ O 2 [92.89±18.37 (73.34-143.63) %predicted]. Each arm ergometer protocol elicited similar V ˙ O 2 (1.37±0.31, 1.35±0.32, 1.34±0.31 and 1.33±0.30 L/min, P=0.99), HR (P=0.96), V ˙ E (P=0.98), VT (P=0.98) and Bf (P=0.81) at peak and AT (P=0.96). However, there were significantly different peak work rate (58±11, 80±18, 95±22 and 110±22 W, P

Schlagwörter

Stichwörter der Autor:innen

Cardiopulmonary exercise testing (CPET)arm ergometerleg ergometerprotocol optimizationwork rate increasing rate

Autor:innen und Institutionen

  • Department of Rehabilitation Medicine, The Affiliated Rehabilitation Hospital of Chongqing Medical University, Chongqing, China.
  • Department of Functional Testing Center, State Key Laboratory of Cardiovascular Disease, Fuwai Hospital, National Center for Cardiovascular Diseases, National Research Center of Clinical Medicine for Cardiovascular Dise…

Zitieren

APA

Zhang, Z. F., Sun, X. G., Chen, J. H., Xu, F., Xiang, M. J., Huang, J., Xie, B., Shi, C., Zhang, Y. F., Liu, F., Li, L., & Xie, Y. H. (2025). The effect of different work rate increasing rates on cardiopulmonary exercise testing in arm ergometer. Journal of Thoracic Disease, 17(9), 7124-7140. https://doi.org/10.21037/jtd-24-531

Vancouver

Zhang ZF, Sun XG, Chen JH, Xu F, Xiang MJ, Huang J, et al. The effect of different work rate increasing rates on cardiopulmonary exercise testing in arm ergometer. Journal of Thoracic Disease. 2025;17(9):7124-7140. doi:10.21037/jtd-24-531

BibTeX
@article{Zhang2025,
  author = {Zhang, Zeng-Fei and Sun, Xing-Guo and Chen, Jia-Hao and Xu, Fan and Xiang, Meng-Jun and Huang, Jiang and Xie, Ben and Shi, Chao and Zhang, Yan-Fang and Liu, Fang and Li, Lin and Xie, You-Hong},
  title = {The effect of different work rate increasing rates on cardiopulmonary exercise testing in arm ergometer},
  journal = {Journal of Thoracic Disease},
  year = {2025},
  volume = {17},
  number = {9},
  pages = {7124--7140},
  doi = {10.21037/jtd-24-531}
}
Kostenlos starten →