Inter-Rater Reliability of Carotid Intima-Media Thickness Measurements in a Multicenter Cohort Study
Journal of Health Informatics and Statistics · 2016
DOI: 10.21032/jhis.2016.41.1.49 ↗Kurz gefasst
Kohortenstudie in der Zeitschrift Journal of Health Informatics and Statistics, 2016. Verfasst von Jung Hyun Lee und 5 weiteren Autor:innen. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 24 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 3.0). Gefördert von: Ministry of Health and Welfare.
Abstract (Originalsprache)
Objectives
Carotid intima-media thickness (CIMT) and the presence of carotid artery plaque are widely used as preclinical markers of atherosclerosis.Due to operator dependency in measuring CIMT, it is important to evaluate the reliability of measuring CIMT and plaque between centers in a multicenter study.The purpose of this study is to evaluate the inter-rater reliability of CIMT and plaque presence among three clinical centers of the Cardiovascular and Metabolic Disease Etiology Research Center (CMERC).
Methods
Twenty people without known cardiovascular disease (age 37-64) were enrolled during 2014-2015, and their left and right carotid arteries were examined repeatedly with ultrasonography for CIMT measurements at three clinical centers according to a predetermined protocol.Maximum and mean values of CIMT at distal common carotid artery were recorded.Plaque presence at a carotid artery was checked by an operator.The reliability of CIMT and carotid plaque presence was assessed using an intraclass correlation coefficient (ICC) and kappa statistics, respectively.
Results
Calculated ICC was 0.647 (95% CI: 0.487-0.779)for maximum CIMT, and 0.758 (95% CI: 0.632-0.854)for mean CIMT.In Bland Altman plot, most observed values were distributed within mean difference ± 1.96 SD ranges.Kappa statistics of plaque presence between two centers were 0.304 (center 1 and 2), 0.507 (center 1 and 3), and 0.606 (center 2 and 3), respectively, while Fleiss kappa for overall agreement was 0.445.
Conclusions
The inter-rater reliability of CIMT measurements among three clinical centers turned out to be high, and the agreement of measuring carotid plaque presence was fair.
Förderung
- Ministry of Health and Welfare
Zitieren
APA
Lee, J. H., Choi, D. P., Shim, J., Kim, D. J., Park, S., & Kim, H. C. (2016). Inter-Rater Reliability of Carotid Intima-Media Thickness Measurements in a Multicenter Cohort Study. Journal of Health Informatics and Statistics. https://doi.org/10.21032/jhis.2016.41.1.49
Vancouver
Lee JH, Choi DP, Shim J, Kim DJ, Park S, Kim HC. Inter-Rater Reliability of Carotid Intima-Media Thickness Measurements in a Multicenter Cohort Study. Journal of Health Informatics and Statistics. 2016. doi:10.21032/jhis.2016.41.1.49
BibTeX
@article{Lee2016,
author = {Lee, Jung Hyun and Choi, Dong Phil and Shim, Jee-Seon and Kim, Dae Jung and Park, Sung-Ha and Kim, Hyeon Chang},
title = {Inter-Rater Reliability of Carotid Intima-Media Thickness Measurements in a Multicenter Cohort Study},
journal = {Journal of Health Informatics and Statistics},
year = {2016},
doi = {10.21032/jhis.2016.41.1.49}
}
EUVIMED