EUVIMEDEUVIMED entdecken
Crossref

Enhanced Tumor Detection in Soft Tissues: A New Approach Combining Multiple Vibration Needle Frequencies

Pham Thi Thu Ha, Pham Duy Phong, Quang Hai Luong, Vijender Kumar Solanki, Duc Tan Tran

VFAST Transactions on Software Engineering · 31.05.2026 · 14 (2) · 179-191

DOI: 10.21015/vtse.v14i2.2387 ↗

Kurz gefasst

Fachartikel in der Zeitschrift VFAST Transactions on Software Engineering, online erschienen am 31.05.2026. Verfasst von Pham Thi Thu Ha und 4 weiteren Autor:innen. Die Arbeit nennt 40 Literaturangaben.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The determination of tissue viscosity and elasticity is essential for characterizing tissue structures and detecting tumors. Researchers have explored various approaches, including the integration of the Least Mean Square (LMS) filter with the Algebraic Helmholtz Inversion (AHI) technique and the use of specific frequency combinations, such as 100 Hz and 150 Hz, as demonstrated in previous studies. This paper investigates the optimization of vibration needle frequencies for tumor detection, emphasizing the importance of tailoring frequency combinations based on tumor location. The study highlights that initial tumor detection should be conducted within the 100-120 Hz range to minimize estimation errors. Normalized errors of viscosity and elasticity serve as key performance indicators. The results demonstrate that the selection of appropriate frequency combinations based on the initial location of the tumor significantly reduces the viscosity and elasticity estimation errors, thus improving the detection accuracy. Specifically, for a tumor located at coordinate (40,40), the elasticity error was reduced from 1.277 to 0.2258, while the viscosity error decreased from 0.1096 to 0.0352. Additionally, this study provides valuable information on optimizing vibration needle frequencies for tumors located at varying distances from the stimulation source. By refining frequency selection strategies, this research contributes to improving soft tissue characterization techniques, ultimately leading to more precise and reliable tumor detection methods.

Zitieren

APA

Ha, P. T. T., Phong, P. D., Luong, Q. H., Solanki, V. K., & Tran, D. T. (2026). Enhanced Tumor Detection in Soft Tissues: A New Approach Combining Multiple Vibration Needle Frequencies. VFAST Transactions on Software Engineering, 14(2), 179-191. https://doi.org/10.21015/vtse.v14i2.2387

Vancouver

Ha PTT, Phong PD, Luong QH, Solanki VK, Tran DT. Enhanced Tumor Detection in Soft Tissues: A New Approach Combining Multiple Vibration Needle Frequencies. VFAST Transactions on Software Engineering. 2026;14(2):179-191. doi:10.21015/vtse.v14i2.2387

BibTeX
@article{Ha2026,
  author = {Ha, Pham Thi Thu and Phong, Pham Duy and Luong, Quang Hai and Solanki, Vijender Kumar and Tran, Duc Tan},
  title = {Enhanced Tumor Detection in Soft Tissues: A New Approach Combining Multiple Vibration Needle Frequencies},
  journal = {VFAST Transactions on Software Engineering},
  year = {2026},
  volume = {14},
  number = {2},
  pages = {179--191},
  doi = {10.21015/vtse.v14i2.2387}
}
Kostenlos starten →