EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Flexible calibration method: Photometric and radiometric measurements with compact low-cost multi-channel sensors

Alberto Besozzi, Giovanni Gibertoni, Luigi Rovati, Agostino Gibaldi

Acta IMEKO · 04.06.2026 · 15 (2) · 1-12

DOI: 10.21014/actaimeko.v15i2.2267 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Acta IMEKO, online erschienen am 04.06.2026. Verfasst von Alberto Besozzi und 3 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Compact multi-spectral sensors present a cost-effective solution for portable light measurement, yet their radiometric accuracy and spectral reconstruction capabilities remain under-characterised compared to laboratory-grade spectroradiometers. This study presents a systematic method for evaluating and calibrating a commercial sensor with a discrete set of spectral channels. The absolute radiometric responsivity was characterized using both laboratory-standard and readily accessible illumination sources, thereby demonstrating that the calibration is independent of the particular light source. Furthermore, the spectral power distribution reconstruction was evaluated under various illumination conditions, correctly estimating radiometric and photometric quantities for visual and non-visual systems. The results also show that increasing the number of spectral channels improves reconstruction accuracy primarily when the channels are well distributed over the spectral range, while additional overlapping bands provide only marginal benefits. This work is a step towards unified methodologies and infrastructure for standardised measurement tools and reproducible calibration.

Zitieren

APA

Besozzi, A., Gibertoni, G., Rovati, L., & Gibaldi, A. (2026). Flexible calibration method: Photometric and radiometric measurements with compact low-cost multi-channel sensors. Acta IMEKO, 15(2), 1-12. https://doi.org/10.21014/actaimeko.v15i2.2267

Vancouver

Besozzi A, Gibertoni G, Rovati L, Gibaldi A. Flexible calibration method: Photometric and radiometric measurements with compact low-cost multi-channel sensors. Acta IMEKO. 2026;15(2):1-12. doi:10.21014/actaimeko.v15i2.2267

BibTeX
@article{Besozzi2026,
  author = {Besozzi, Alberto and Gibertoni, Giovanni and Rovati, Luigi and Gibaldi, Agostino},
  title = {Flexible calibration method: Photometric and radiometric measurements with compact low-cost multi-channel sensors},
  journal = {Acta IMEKO},
  year = {2026},
  volume = {15},
  number = {2},
  pages = {1--12},
  doi = {10.21014/actaimeko.v15i2.2267}
}
Kostenlos starten →