Optical sensing for real-time blood monitoring in extracorporeal circulation: Performance assessment of a biocompatible sensor and off-label investigation of a commercial device
Acta IMEKO · 28.06.2026 · 15 (2) · 1-8
DOI: 10.21014/actaimeko.v15i2.2263 ↗Kurz gefasst
Fachartikel in der Zeitschrift Acta IMEKO, online erschienen am 28.06.2026. Verfasst von Alessia Gallerani und 4 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Continuous monitoring of blood pCO2 is critical during extracorporeal circulation (ECC) to support clinical decision-making. This study aims to describe and investigate a new, low-cost, disposable fluorescent pCO2 sensor, namely MS2. The performance of MS2 is analysed by comparison with a blood gas analyzer. A significant challenge in developing sensors for in vivo applications is ensuring biocompatibility. In the MS2 sensor, biocompatibility is ensured by using a medical-grade gas-permeable membrane that isolates the sensing chemistry from the patient’s blood. The study also investigates the performance of a commercial optical pCO2 sensor, the PreSens MCR-O1P1C1, which is not approved for use with blood. The aim is to assess the feasibility of employing the PreSens MCR-O1P1C1 for blood monitoring in scenarios where biocompatibility is not a prerequisite, such as in the development stages of biomedical devices that require ex vivo blood testing. The results obtained during a 6.5-hour test with bovine blood demonstrate that both measuring systems can provide valid support for monitoring pCO2 in blood. However, despite its excellent response times, the off-label application of the PreSens MCR-O1P1C1 necessitates an adjustment of the measuring system to prevent significant measurement errors. Thus, these results position MS2 as a promising solution for real-time, in-line blood gas monitoring in ECC procedures.
Zitieren
APA
Gallerani, A., Muzzarelli, M., Ferrari, A., Cattini, S., & Rovati, L. (2026). Optical sensing for real-time blood monitoring in extracorporeal circulation: Performance assessment of a biocompatible sensor and off-label investigation of a commercial device. Acta IMEKO, 15(2), 1-8. https://doi.org/10.21014/actaimeko.v15i2.2263
Vancouver
Gallerani A, Muzzarelli M, Ferrari A, Cattini S, Rovati L. Optical sensing for real-time blood monitoring in extracorporeal circulation: Performance assessment of a biocompatible sensor and off-label investigation of a commercial device. Acta IMEKO. 2026;15(2):1-8. doi:10.21014/actaimeko.v15i2.2263
BibTeX
@article{Gallerani2026,
author = {Gallerani, Alessia and Muzzarelli, Marco and Ferrari, Alberto and Cattini, Stefano and Rovati, Luigi},
title = {Optical sensing for real-time blood monitoring in extracorporeal circulation: Performance assessment of a biocompatible sensor and off-label investigation of a commercial device},
journal = {Acta IMEKO},
year = {2026},
volume = {15},
number = {2},
pages = {1--8},
doi = {10.21014/actaimeko.v15i2.2263}
}
EUVIMED