EUVIMEDEUVIMED entdecken
Crossref

Erratum for “Performance Evaluation of Conductive Fiber-Coated Twisted and Coiled Polymer Actuator (TCPA) Unit with a Helical Fiber Structure” (Vol.38, pp. 329-340, 2026)

Masataka Nakabayashi, Yuhi Tamura, Ayana Mikuni

Journal of Robotics and Mechatronics · 20.08.2026 · 38 (4) · 1174-1174

DOI: 10.20965/jrm.2026.p1174 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Robotics and Mechatronics, online erschienen am 20.08.2026. Verfasst von Masataka Nakabayashi und 2 weiteren Autor:innen. Die Arbeit nennt 21 Literaturangaben.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Original article: Journal of Robotics and Mechatronics, Vol.38, No.1, pp. 329-340, 2024. doi: https://doi.org/10.20965/jrm.2026.p0329 Upon further review of this article, the authors noticed errors on page 333 that they would like to correct. This error occurred unintentionally during the unit conversion and manuscript preparation process. The correction does not change any of the conclusions. Originally published text Corrected text Section 4.1: In the current system, the rotational speeds of SM1 and SM2, which perform the twist operation on the precursor fiber, were maintained at 90 rpm, whereas the feed speed provided by SM3 was manually adjusted for tension control, as previously described. Section 4.1: In the current system, the rotational speeds of SM1 and SM2, which perform the twist operation on the precursor fiber, were maintained at 27 rpm, whereas the feed speed provided by SM3 was manually adjusted for tension control, as previously described. Section 4.3: In addition, while the previous report set the rotational speeds of SM1 and SM2 at 30 rpm, this study used 90 rpm to accommodate the production of longer TCPAs, which might have adversely affected the twisting process stability. Section 4.3: In addition, while the previous report set the rotational speeds of SM1 and SM2 at 9 rpm, this study used 27 rpm to accommodate the production of longer TCPAs, which might have adversely affected the twisting process stability. The authors regret this error, and this error has now been corrected in the PDF version of the article.

Zitieren

APA

Nakabayashi, M., Tamura, Y., & Mikuni, A. (2026). Erratum for “Performance Evaluation of Conductive Fiber-Coated Twisted and Coiled Polymer Actuator (TCPA) Unit with a Helical Fiber Structure” (Vol.38, pp. 329-340, 2026). Journal of Robotics and Mechatronics, 38(4), 1174-1174. https://doi.org/10.20965/jrm.2026.p1174

Vancouver

Nakabayashi M, Tamura Y, Mikuni A. Erratum for “Performance Evaluation of Conductive Fiber-Coated Twisted and Coiled Polymer Actuator (TCPA) Unit with a Helical Fiber Structure” (Vol.38, pp. 329-340, 2026). Journal of Robotics and Mechatronics. 2026;38(4):1174-1174. doi:10.20965/jrm.2026.p1174

BibTeX
@article{Nakabayashi2026,
  author = {Nakabayashi, Masataka and Tamura, Yuhi and Mikuni, Ayana},
  title = {Erratum for “Performance Evaluation of Conductive Fiber-Coated Twisted and Coiled Polymer Actuator (TCPA) Unit with a Helical Fiber Structure” (Vol.38, pp. 329-340, 2026)},
  journal = {Journal of Robotics and Mechatronics},
  year = {2026},
  volume = {38},
  number = {4},
  pages = {1174--1174},
  doi = {10.20965/jrm.2026.p1174}
}
Kostenlos starten →