EUVIMEDEUVIMED entdecken
Crossref

Test station for evaluation of shaped catalysts for passive autocatalytic recombiners

Sergio Ricardo Catharino Mello, Renato Paulo Rezende, Jose Alfredo Gulielmino, Marcus Augusto Tadeu Arnold, Gabriel Takaoka, Lorenzo De Micheli, Claudia Giovedi, Isa Carolina Silva Costa, Camila Emilia Kozonoe, Jorge Moreira Vaz, Estevam Vitorio Spinacé

Academia Catalysis · 29.07.2026 · 2 (3)

DOI: 10.20935/acadcatal8454 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Academia Catalysis, online erschienen am 29.07.2026. Verfasst von Sergio Ricardo Catharino Mello und 10 weiteren Autor:innen. Die Arbeit nennt 18 Literaturangaben.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

Passive autocatalytic recombiners (PARs) are key safety devices used in nuclear power plants to mitigate hydrogen accumulation during severe accidents through the catalytic recombination of hydrogen and oxygen. The development of shaped catalysts for PAR applications requires testing under representative operating conditions; however, most laboratory studies evaluate powdered catalysts in conventional fixed-bed reactors, which do not accurately reproduce PAR operating conditions. Technical methodology: A dedicated test station was designed and constructed to evaluate shaped catalysts under conditions closely resembling those found in commercial PAR systems. The setup employs a rectangular mesh cartridge filled with spherical catalysts, allowing real-time monitoring of gas temperature and hydrogen conversion. Eggshell-type Pd/Al2O3 spherical catalysts containing 0.25 and 0.50 wt% Pd were prepared and characterized by CO chemisorption to determine Pd active surface area, particle size, and metal dispersion. Catalytic performance was evaluated using 35 g of catalyst under a flow of 3 vol% H2 in synthetic air at 2.5 L min−1.

Results

The developed testing station reproduces the gas-flow configuration encountered in commercial PAR devices while enabling simultaneous measurement of catalyst temperature and hydrogen conversion. The catalyst containing 0.50 wt% Pd achieved approximately 90% hydrogen conversion within 15 s and complete conversion after approximately 600 s, whereas the 0.25 wt% Pd catalyst reached 92.4% conversion under steady-state conditions. Normalization of the results by the Pd active surface area yielded specific catalytic activities of 0.13 and 0.18 g H2 h−1 m−2 for the 0.50 and 0.25 wt% Pd catalysts, respectively. These values are comparable to those reported for commercial PAR systems, demonstrating the reliability of the developed methodology for catalyst evaluation.

Conclusions

The proposed test station provides a rapid and reliable platform for evaluating shaped catalysts under representative PAR operating conditions. The methodology enables direct comparison of catalyst performance based on Pd active surface area and represents a valuable tool for the development and optimization of catalysts for passive autocatalytic recombiners, contributing to improved hydrogen safety in nuclear facilities and other hydrogen-based energy systems.

Zitieren

APA

Mello, S. R. C., Rezende, R. P., Gulielmino, J. A., Arnold, M. A. T., Takaoka, G., Micheli, L. D., Giovedi, C., Costa, I. C. S., Kozonoe, C. E., Vaz, J. M., & Spinacé, E. V. (2026). Test station for evaluation of shaped catalysts for passive autocatalytic recombiners. Academia Catalysis, 2(3). https://doi.org/10.20935/acadcatal8454

Vancouver

Mello SRC, Rezende RP, Gulielmino JA, Arnold MAT, Takaoka G, Micheli LD, et al. Test station for evaluation of shaped catalysts for passive autocatalytic recombiners. Academia Catalysis. 2026;2(3). doi:10.20935/acadcatal8454

BibTeX
@article{Mello2026,
  author = {Mello, Sergio Ricardo Catharino and Rezende, Renato Paulo and Gulielmino, Jose Alfredo and Arnold, Marcus Augusto Tadeu and Takaoka, Gabriel and Micheli, Lorenzo De and Giovedi, Claudia and Costa, Isa Carolina Silva and Kozonoe, Camila Emilia and Vaz, Jorge Moreira and Spinacé, Estevam Vitorio},
  title = {Test station for evaluation of shaped catalysts for passive autocatalytic recombiners},
  journal = {Academia Catalysis},
  year = {2026},
  volume = {2},
  number = {3},
  doi = {10.20935/acadcatal8454}
}
Kostenlos starten →