EUVIMEDEUVIMED entdecken
Crossref

Biodegradable, self-powered E-skin for contactless respiratory and epidermal humidity monitoring

Xuetao Zhang, Qing Yue, Hongwei Sheng, Jiao Yuan, Lingxiao Ma, Haoshuo Zhang, Mingjiao Shao, Huasheng Bi, Jinkun Hu, Qing Su, Wei Lan

Soft Science · 31.10.2025 · 5 (4)

DOI: 10.20517/ss.2025.55 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Soft Science, online erschienen am 31.10.2025. Verfasst von Xuetao Zhang und 10 weiteren Autor:innen. Die Arbeit wurde bisher 16-mal zitiert (Crossref) und nennt 38 Literaturangaben.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Humidity monitoring is vital for respiratory health assessment, yet conventional sensors lack flexibility, back-end power supply, and environmental friendliness, demanding flexible, self-powered, and biodegradable devices. Here, we developed a flexible, fully biodegradable self-powered electronic skin (E-skin) that seamlessly integrates micro-supercapacitors (MSCs) and a humidity sensor. Highly hygroscopic agarose (AG) was selected as both the substrate and gel electrolyte, with Ti3C2Tx MXene nanosheet-based interdigital electrode arrays patterned on its surface via in-situ fabrication. No metal interconnects or polymer binders were introduced during the whole fabrication process. The MSCs based on AG/sweat gel electrolyte exhibited high area capacitance (15.6 mF·cm-2), long-term cycling stability (up to 10,000 cycles), and desired biodegradable properties. Due to the strong interaction between AG and MXene with water molecules by abundant hydrophilic groups such as hydroxyl, the humidity sensor has high sensitivity and a good linear relationship within the range of 11%-97% relative humidity. The integrated E-skin system enables real-time monitoring of human breathing patterns (including the mouth and nose), as well as the humidity levels of non-contact finger touch and skin. This work paves the way for sustainable, self-sufficient wearable electronics in personalized respiratory monitoring.

Zitieren

APA

Zhang, X., Yue, Q., Sheng, H., Yuan, J., Ma, L., Zhang, H., Shao, M., Bi, H., Hu, J., Su, Q., & Lan, W. (2025). Biodegradable, self-powered E-skin for contactless respiratory and epidermal humidity monitoring. Soft Science, 5(4). https://doi.org/10.20517/ss.2025.55

Vancouver

Zhang X, Yue Q, Sheng H, Yuan J, Ma L, Zhang H, et al. Biodegradable, self-powered E-skin for contactless respiratory and epidermal humidity monitoring. Soft Science. 2025;5(4). doi:10.20517/ss.2025.55

BibTeX
@article{Zhang2025,
  author = {Zhang, Xuetao and Yue, Qing and Sheng, Hongwei and Yuan, Jiao and Ma, Lingxiao and Zhang, Haoshuo and Shao, Mingjiao and Bi, Huasheng and Hu, Jinkun and Su, Qing and Lan, Wei},
  title = {Biodegradable, self-powered E-skin for contactless respiratory and epidermal humidity monitoring},
  journal = {Soft Science},
  year = {2025},
  volume = {5},
  number = {4},
  doi = {10.20517/ss.2025.55}
}
Kostenlos starten →