A multi-channel photoplethysmography array with contact-force regulation for tonoarteriographic imaging
Connected Health And Telemedicine · 19.02.2024 · 3 (1)
DOI: 10.20517/chatmed.2023.11 ↗Kurz gefasst
Fachartikel in der Zeitschrift Connected Health And Telemedicine, online erschienen am 19.02.2024. Verfasst von Zi-Jun Liu und 4 weiteren Autor:innen. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 20 Literaturangaben.
Abstract (Originalsprache)
Aim
Photoplethysmography (PPG) has gained widespread popularity as a non-invasive method for potential cuff-less blood pressure (BP) measurement in smart devices. However, the accuracy of PPG-based devices is often hindered by motion artifacts, site variability, and inconsistent contact force (CF). This study aims to investigate the influence of CF variations on PPG signals.
Methods
To address these challenges, we present a novel approach involving a multi-channel PPG array integrated with CF regulation in the form of a wearable wristband. This platform enables the visualization of regional PPG/BP distribution while simultaneously monitoring CF. Moreover, our research explored the relationship between PPG waveform characteristics and CF during wrist extension.
Results
The results of this study reveal that the PPG amplitude (PPGA) and the b/a ratios, computed from the second derivative peaks of the PPG AC pulse wave, exhibit inconsistency in reaction to CF variations. Notably, a shape correlation coefficient of 0.65069 between normalized PPG and flipped CF sheds light on how changes in posture affect PPG measurements.
Conclusions
The proposed platform shows promise in mitigating the effects of CF and spatial positioning on PPG, thereby improving measurement precision and offering a novel approach to image tonoarteriographic (TAG) activities for continuous hypertension management.
Zitieren
APA
Liu, Z., Xiang, T., Zhou, R., Ji, N., & Zhang, Y. (2024). A multi-channel photoplethysmography array with contact-force regulation for tonoarteriographic imaging. Connected Health And Telemedicine, 3(1). https://doi.org/10.20517/chatmed.2023.11
Vancouver
Liu Z, Xiang T, Zhou R, Ji N, Zhang Y. A multi-channel photoplethysmography array with contact-force regulation for tonoarteriographic imaging. Connected Health And Telemedicine. 2024;3(1). doi:10.20517/chatmed.2023.11
BibTeX
@article{Liu2024,
author = {Liu, Zi-Jun and Xiang, Ting and Zhou, Ru-Shuang and Ji, Nan and Zhang, Yuan-Ting},
title = {A multi-channel photoplethysmography array with contact-force regulation for tonoarteriographic imaging},
journal = {Connected Health And Telemedicine},
year = {2024},
volume = {3},
number = {1},
doi = {10.20517/chatmed.2023.11}
}
EUVIMED