18F-fluorodeoxyglucose and 18F-sodium fluoride positron emission tomography imaging in assessing early stages of aortic valve degeneration after transcatheter aortic valve implantation
Polish Archives of Internal Medicine · 2023
DOI: 10.20452/pamw.16607 ↗Kurz gefasst
Fachartikel in der Zeitschrift Polish Archives of Internal Medicine, 2023. Verfasst von Danuta Sorysz und 8 weiteren Autor:innen. Beteiligte Einrichtung: Clinical Department of Cardiology and Cardiovascular Interventions, University Hospital, Kraków, Poland; Second Department of Cardiology, Institute o…. Hauptthemen laut MEDLINE: Fluorodeoxyglucose F18, Transcatheter Aortic Valve Replacement.
Abstract (Originalsprache)
INTRODUCTION: Transcatheter aortic valve implantation (TAVI) is a standard treatment for severe aortic stenosis, primarily in elderly patients. With an increasing number of procedures and younger patients, understanding the valve degeneration and its risk factors becomes crucial. OBJECTIVES: We aimed to utilize 18F‑sodium fluoride (18F‑NaF) and 18F‑fluorodeoxyglucose (18F‑FDG) positron emission tomography/computed tomography (PET/CT) to evaluate early TAVI valve degeneration. PATIENTS AND METHODS: In this prospective study with a prespecified follow‑up protocol, 71 TAVI patients underwent baseline transthoracic and transesophageal echocardiography, and PET/CT with 18F‑NaF and 18F‑FDG. Of these, 31 patients completed 24‑month control examinations, while the others were lost to mortality and the COVID‑19 pandemic. We measured PET tracer activity and compared 18F‑NaF and 18F‑FDG PET/CT uptake at baseline and 24‑month follow‑up. RESULTS: PET/CT and echocardiography data were analyzed for 31 of the 71 enrolled TAVI patients at a median age of 84 years (interquartile range, 80-86). After TAVI, an improvement in the valve function was observed. During follow‑up, the valve function remained stable. PET/CT demonstrated an increase in 18F‑FDG maximal uptake in the inner (tissue‑to‑background ratio, P = 0.009) and outer (P = 0.01) sides of the TAVI valve stent, but no difference in 18F‑NaF maximal activity (inner, P = 0.17; outer, P = 0.57). CONCLUSIONS: Twenty‑four months post‑TAVI, an increase in 18F‑FDG uptake, indicative of inflammation, was observed in the valve, while the uptake of the calcification marker (18F‑NaF) remained stable. Theseobservations might suggest early stages of TAVI valve degeneration, although further investigation is required to confirm this interpretation.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- Clinical Department of Cardiology and Cardiovascular Interventions, University Hospital, Kraków, Poland; Second Department of Cardiology, Institute of Cardiology, Jagiellonian University Medical College, Kraków, Poland.…
- Clinical Department of Cardiology and Cardiovascular Interventions, University Hospital, Kraków, Poland
- Second Department of Cardiology, Institute of Cardiology, Jagiellonian University Medical College, Kraków, Poland
- Clinical Department of Endocrinology, Oncological Endocrinology and Nuclear Medicine, University Hospital, Kraków, Poland
- Department of Endocrinology, Jagiellonian University Medical College, Kraków, Poland
- Department of Radiology, University Hospital, Kraków, Poland
Zitieren
APA
Sorysz, D., Dziewierz, A., Opalinska, M., Sowa-Staszczak, A., Grochowska, A., Malinowski, K. P., Maruszak, N., Bartuś, S., & Dudek, D. (2023). 18F-fluorodeoxyglucose and 18F-sodium fluoride positron emission tomography imaging in assessing early stages of aortic valve degeneration after transcatheter aortic valve implantation. Polish Archives of Internal Medicine. https://doi.org/10.20452/pamw.16607
Vancouver
Sorysz D, Dziewierz A, Opalinska M, Sowa-Staszczak A, Grochowska A, Malinowski KP, et al. 18F-fluorodeoxyglucose and 18F-sodium fluoride positron emission tomography imaging in assessing early stages of aortic valve degeneration after transcatheter aortic valve implantation. Polish Archives of Internal Medicine. 2023. doi:10.20452/pamw.16607
BibTeX
@article{Sorysz2023,
author = {Sorysz, Danuta and Dziewierz, Artur and Opalinska, Marta and Sowa-Staszczak, Anna and Grochowska, Anna and Malinowski, Krzysztof P and Maruszak, Natalia and Bartuś, Stanisław and Dudek, Dariusz},
title = {18F-fluorodeoxyglucose and 18F-sodium fluoride positron emission tomography imaging in assessing early stages of aortic valve degeneration after transcatheter aortic valve implantation},
journal = {Polish Archives of Internal Medicine},
year = {2023},
doi = {10.20452/pamw.16607}
}
EUVIMED