Pulmonary Artery Thrombus Presenting as Cyanotic Cardiac Defect in a Neonate
ARC Journal of Clinical Case Reports · 2016
DOI: 10.20431/2455-9806.0201005 ↗Kurz gefasst
Fachartikel in der Zeitschrift ARC Journal of Clinical Case Reports, 2016.
Abstract (Originalsprache)
Background
Pulmonary artery thrombosis presenting as pulmonary arterial hypertension (PAH) is a known entity in adult patients but presentation in neonate is very rare.Case characteristics: Two days old neonate, presented with PAH with cyanosis, diagnosed with thrombus involving main and left pulmonary artery causing complete occlusion of left.
Intervention
Pulmonary artery thrombolysis was done with tissue plasminogen activator (tPA) followed by heparin for 3 months.Outcome: There was complete dissolution of thrombus after thrombolysis.Message: When assessing a neonate with cyanosis and PAH, pulmonary artery thrombi should be ruled out before labeling it as PPHN.
Zitieren
APA
(2016). Pulmonary Artery Thrombus Presenting as Cyanotic Cardiac Defect in a Neonate. ARC Journal of Clinical Case Reports. https://doi.org/10.20431/2455-9806.0201005
Vancouver
Pulmonary Artery Thrombus Presenting as Cyanotic Cardiac Defect in a Neonate. ARC Journal of Clinical Case Reports. 2016. doi:10.20431/2455-9806.0201005