EUVIMEDEUVIMED entdecken
Crossref

Impact of Labor Variables on The Anterior and Posterior Fontanels Morphometry of Newborn: Across Sectional Study In AL-Gezira State, Sudan

Omnia M. Medani Elhadi, Mohamed Kheir E.A. Elkarim, Nurein M. A, Ammar Elmajzoub

Yemeni Journal for Medical Sciences · 18.06.2026 · 20 (4)

DOI: 10.20428/yjms.v20i4.3715 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Yemeni Journal for Medical Sciences, online erschienen am 18.06.2026. Verfasst von Omnia M. Medani Elhadi und 3 weiteren Autor:innen.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

The fontanelle size allows the early detection of several clinical disorders concerning the development of the skeleton and brain. There is debate on a defined range of fontanelle sizes, even though authors acknowledge that they vary. Variations are linked to a variety of factors, including labor.

Objective

In the central Sudanese state of Al-Gezira, this study intended to elucidate the relationship between labor factors and the size of the anterior and posterior fontanelles in newborn Sudanese children.

Methods

This cross-sectional observational study included 400 mothers and their babies (term and preterm) born at Wad Madani Obstetrics and Gynecology Hospital. Newborn with congenital malformation, cephalohematoma, and caput succedaneum; newborn with obvious chromosomal abnormality. And babies with neurological problems were excluded in this study. The women's delivery mode, baby presentation, labor length, and fontanel size were measured using the Popich and Smith protocols. T-tests and one-way ANOVA were employed to look at the results. Results: a significant correlation between the PFS (p = 0.017) and AFS (p = 0.001) and the mode of delivery. There was a discernible increase in AFS for the group that had a cesarean section compared to those who had a vaginal delivery. There was a significant correlation between the baby's presentation and both AFS (p=0.001) and PFS (p=0.001). The duration of labor significantly affects only the anterior fontanelle (p = 0.014). not the posterior (p = 0.45). Conclusion: the study identified significant correlations between obstetric variables and neonatal fontanelle morphometry. These findings suggest that the physical mechanics and duration of labor are primary determinants of fontanelle size in the immediate neonatal period, necessitating clinical consideration during initial physical assessments.

Zitieren

APA

Elhadi, O. M. M., Elkarim, M. K. E., A, N. M., & Elmajzoub, A. (2026). Impact of Labor Variables on The Anterior and Posterior Fontanels Morphometry of Newborn: Across Sectional Study In AL-Gezira State, Sudan. Yemeni Journal for Medical Sciences, 20(4). https://doi.org/10.20428/yjms.v20i4.3715

Vancouver

Elhadi OMM, Elkarim MKE, A NM, Elmajzoub A. Impact of Labor Variables on The Anterior and Posterior Fontanels Morphometry of Newborn: Across Sectional Study In AL-Gezira State, Sudan. Yemeni Journal for Medical Sciences. 2026;20(4). doi:10.20428/yjms.v20i4.3715

BibTeX
@article{Elhadi2026,
  author = {Elhadi, Omnia M. Medani and Elkarim, Mohamed Kheir E.A. and A, Nurein M. and Elmajzoub, Ammar},
  title = {Impact of Labor Variables on The Anterior and Posterior Fontanels Morphometry of Newborn: Across Sectional Study In AL-Gezira State, Sudan},
  journal = {Yemeni Journal for Medical Sciences},
  year = {2026},
  volume = {20},
  number = {4},
  doi = {10.20428/yjms.v20i4.3715}
}
Kostenlos starten →