EUVIMEDEUVIMED entdecken
Open Access

Incidence and risk factors for peripheral intravenous catheter failure in Japanese neonatal intensive care units and growing care units: a multicenter observational study

Shun Yamamoto, Ryoko Murayama

Fujita Medical Journal · 2026-05 · 12 (2) · 135-142

DOI: 10.20407/fmj.2025-027 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Fujita Medical Journal, 2026-05. Verfasst von Shun Yamamoto und 1 weiteren Autor:innen. Beteiligte Einrichtung: Graduate School of Health Sciences, Fujita Health University, Toyoake, Aichi, Japan. Der Volltext ist frei in PubMed Central verfügbar.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objectives

Peripheral intravenous catheters (PIVCs) are used in neonatal intensive care units (NICUs) and growing care units (GCUs). However, neonates/infants in these units frequently experience catheter failure (CF) because of complications, such as extravasation and phlebitis. Nonetheless, data on PIVCs from Japan remain limited. Therefore, this study aimed to investigate the use of infusion catheters and the incidence, characteristics, and risk factors of PIVC-related catheter failure in Japanese NICUs and GCUs.

Methods

This study was conducted between August 2024 and February 2025 using cross-sectional and prospective surveys. Data from 600 hospitalized neonates/infants and 259 PIVC cases were analyzed. CF was defined as unplanned catheter removal before the completion of therapy owing to loss of function or an inability to administer fluids.

Results

Overall, 48.0% of neonates/infants had infusion catheters. The incidence proportion of CF was 47.1%, with an incidence density of 173.1/1,000 catheter-days. Extravasation was the most frequently identified cause of CF (95.9%), and swelling and leaking were primary symptoms. Multivariate Cox regression showed that gestational age (hazard ratio=0.96, p=.03) and infusion flow volume at the time of PIVC removal (hazard ratio=1.28/1 mL/h, p

Schlagwörter

Stichwörter der Autor:innen

Catheter failureJapanMulticenter observational studyNICUPeripheral intravenous catheter

Autor:innen und Institutionen

  • Graduate School of Health Sciences, Fujita Health University, Toyoake, Aichi, Japan.
  • Department of Nursing, Faculty of Health Science, Nagoya Aoi University, Nagoya, Aichi, Japan.
  • Faculty of Nursing, School of Health Sciences, Fujita Health University, Toyoake, Aichi, Japan.
  • Research Center for Implementation Nursing Science Initiative, Fujita Health University, Toyoake, Aichi, Japan.

Zitieren

APA

Yamamoto, S., & Murayama, R. (2026). Incidence and risk factors for peripheral intravenous catheter failure in Japanese neonatal intensive care units and growing care units: a multicenter observational study. Fujita Medical Journal, 12(2), 135-142. https://doi.org/10.20407/fmj.2025-027

Vancouver

Yamamoto S, Murayama R. Incidence and risk factors for peripheral intravenous catheter failure in Japanese neonatal intensive care units and growing care units: a multicenter observational study. Fujita Medical Journal. 2026;12(2):135-142. doi:10.20407/fmj.2025-027

BibTeX
@article{Yamamoto2026,
  author = {Yamamoto, Shun and Murayama, Ryoko},
  title = {Incidence and risk factors for peripheral intravenous catheter failure in Japanese neonatal intensive care units and growing care units: a multicenter observational study},
  journal = {Fujita Medical Journal},
  year = {2026},
  volume = {12},
  number = {2},
  pages = {135--142},
  doi = {10.20407/fmj.2025-027}
}