Implementation of a healthcare system for real time monitoring of health parameters
Computer and Decision Making: An International Journal · 07.11.2026 · 3 (8S) · 134-147
DOI: 10.1922/comdem.v3i8s.19150 ↗Kurz gefasst
Fachartikel in der Zeitschrift Computer and Decision Making: An International Journal, online erschienen am 07.11.2026. Verfasst von Dhananjay V. Bansode und 2 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
An IoT-based real-time health monitoring system is essential for monitoring patients in emergency conditions, patients in intensive care units, NEWS score, deterioration, telemonitoring, and reducing trips to patients, manual observation of patients, and storing and analyzing vitals data [1–3]. This study proposed the design and implementation of a healthcare system for real-time monitoring of body health parameters and preliminary risk stratification using the National Early Warning Score 2 (NEWS2). The project focuses on integrating various sensors to collect medical data related to vital signs, such as heart rate (HR), respiration rate (RR), blood oxygen saturation level (SpO2), body temperature, systolic and diastolic blood pressure [4, 5]. Real-time data are collected by the ESP32 SoC microcontroller node and sent to the Raspberry Pi Gateway through Bluetooth. The Raspberry Pi facilitates data acquisition, storage, and retrieval. The database system enables real-time monitoring of health parameters and historical data for trend analysis and medical diagnosis [6, 7]. In addition, real-time vitals are sent to Thing Speak Cloud using the MQTT protocol. This study discusses the hardware setup, sensor integration, database structure, and software implementation. In a pilot of 30 patients, the prototype recorded all five vital signs and computed NEWS2 (23 low, 5 medium, and 2 high risk). Against reference devices (n = 30 paired readings per parameter), the respiratory rate agreed closely (mean bias +0.6 breaths/min, MAE 1.2 breaths/min, r = 0.91) and temperature agreed to within 0.6 °F on average, whereas HR, SpO2 (at low saturation), and blood pressure showed larger errors (MAE 7.6 bpm, 1.7 %, and 7.7 mmHg for HR, SpO2, and systolic BP) that require further calibration. The prototype demonstrates the feasibility of using Raspberry Pi to build scalable and cost-effective solutions for healthcare monitoring. This research contributes to the advancement of technology-driven healthcare solutions with potential applications in remote patient monitoring, telemedicine, public health surveillance, and healthcare assistance.
Zitieren
APA
Bansode, D. V., Ramane, D. V., & Shaligram, A. D. (2026). Implementation of a healthcare system for real time monitoring of health parameters. Computer and Decision Making: An International Journal, 3(8S), 134-147. https://doi.org/10.1922/comdem.v3i8s.19150
Vancouver
Bansode DV, Ramane DV, Shaligram AD. Implementation of a healthcare system for real time monitoring of health parameters. Computer and Decision Making: An International Journal. 2026;3(8S):134-147. doi:10.1922/comdem.v3i8s.19150
BibTeX
@article{Bansode2026,
author = {Bansode, Dhananjay V. and Ramane, Deepa V. and Shaligram, Arvind D.},
title = {Implementation of a healthcare system for real time monitoring of health parameters},
journal = {Computer and Decision Making: An International Journal},
year = {2026},
volume = {3},
number = {8S},
pages = {134--147},
doi = {10.1922/comdem.v3i8s.19150}
}
EUVIMED