EUVIMEDEUVIMED entdecken
Crossref

The Effect of Calcium Hydroxide and File Sızes on the Accuracy of the Electronic Apex Locator in Simulated Immature Teeth

Leyla AYRANCİ, Ahmet ÇETİNKAYA, Serkan ÖZKAN

Middle Black Sea Journal of Health Science · 31.12.2019 · 5 (3) · 273-278

DOI: 10.19127/mbsjohs.665667 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Middle Black Sea Journal of Health Science, online erschienen am 31.12.2019. Verfasst von Leyla AYRANCİ und 2 weiteren Autor:innen. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 24 Literaturangaben.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective

The aim of this research was to appreciate the effects of different file sizes and the presence of calcium hydroxide on the correctness of the electronic apex locator (EAL) at simulated immature teeth.

Methods

In this study, 30 maxillary central teeth were used beforehand extracted due to periodontal reasons. The actual root canal length determined with K-File and measured behind 0.5mm from the apex. In order to simulate an immature tooth, the apical of roots were prepared with a diameter of 1,4mm Gates-Glidden drills and K-Files. Working lengths of samples were measured using the Root ZX by 110-140 K-Files. Each measurement was repeated three times and averaged. Then all the samples were filled with calcium hydroxide medicament and working lengths were determined by the same method. Statistical analysis was performed using the Two-way ANOVA.

Results

The measurements were closer to the actual root canal length as the diameter of the file increased at the presence and absence of calcium hydroxide. However, there was a difference between the presence and absence of calcium hydroxide in the determination of root canal length.

Conclusions

In these experimental study conditions, it was concluded that the presence of calcium hydroxide in simulated immature teeth and file size affect the EAL.

Zitieren

APA

AYRANCİ, L., ÇETİNKAYA, A., & ÖZKAN, S. (2019). The Effect of Calcium Hydroxide and File Sızes on the Accuracy of the Electronic Apex Locator in Simulated Immature Teeth. Middle Black Sea Journal of Health Science, 5(3), 273-278. https://doi.org/10.19127/mbsjohs.665667

Vancouver

AYRANCİ L, ÇETİNKAYA A, ÖZKAN S. The Effect of Calcium Hydroxide and File Sızes on the Accuracy of the Electronic Apex Locator in Simulated Immature Teeth. Middle Black Sea Journal of Health Science. 2019;5(3):273-278. doi:10.19127/mbsjohs.665667

BibTeX
@article{AYRANC2019,
  author = {AYRANCİ, Leyla and ÇETİNKAYA, Ahmet and ÖZKAN, Serkan},
  title = {The Effect of Calcium Hydroxide and File Sızes on the Accuracy of the Electronic Apex Locator in Simulated Immature Teeth},
  journal = {Middle Black Sea Journal of Health Science},
  year = {2019},
  volume = {5},
  number = {3},
  pages = {273--278},
  doi = {10.19127/mbsjohs.665667}
}
Kostenlos starten →