Comparative Evaluation of the Load-Carrying Behavior of Fixed-End Steel Beams Using Different Analysis Methods
Süleyman Demirel Üniversitesi Fen Bilimleri Enstitüsü Dergisi · 24.04.2026 · 30 (1) · 168-183
DOI: 10.19113/sdufenbed.1805609 ↗Kurz gefasst
Fachartikel in der Zeitschrift Süleyman Demirel Üniversitesi Fen Bilimleri Enstitüsü Dergisi, online erschienen am 24.04.2026. Verfasst von Mustafa Berker Alıcıoğlu. Die Arbeit nennt 18 Literaturangaben.
Abstract (Originalsprache)
This study investigates the behavior of seven steel beams with different cross-sections, each 8 m in length and fixed at both ends, fabricated from S235 steel. The cross-sections were selected in accordance with the requirements specified in Section 9 (Subsections 9.2–9.8) of the Regulation on the Design, Calculation, and Construction of Steel Structures (ÇYTHYDE-2018). The beams were modeled using shell elements, and all analyses were conducted using SAP2000 finite element software. Three analysis methods were employed. First, the theoretical load-carrying capacities of the beams were calculated using the equations provided in ÇYTHYDE-2018. Second, a second-order plastic analysis was performed, in which the midspan load (P) was incrementally increased to determine the beams’ plastic capacities. Finally, a buckling analysis was conducted, with the first-mode buckling factor computed to evaluate the beams’ flexural, torsional, and lateral-torsional buckling behavior. A comparison between the analytical (code-based) moment capacities and the nonlinear numerical results indicated percentage differences ranging between 1% and 6% for IPE600, HE300AA, Built up I, HE450A, Box, and Pipe sections, whereas the Built up II section exhibited a significant difference of 93.89%. Consequently, it has been revealed that the equations provided in Clause 9.5 of the ÇYTHYDE-2018 specification require revision. The results indicate that the Built up I exhibits pronounced sensitivity to the combined effects of lateral translation and torsion, whereas the Built up II demonstrates a comparatively balanced stability performance among bending, torsional, and lateral–torsional buckling modes. Nevertheless, the initial loss of stability is most likely to occur through the lateral–torsional buckling mode.
Zitieren
APA
Alıcıoğlu, M. B. (2026). Comparative Evaluation of the Load-Carrying Behavior of Fixed-End Steel Beams Using Different Analysis Methods. Süleyman Demirel Üniversitesi Fen Bilimleri Enstitüsü Dergisi, 30(1), 168-183. https://doi.org/10.19113/sdufenbed.1805609
Vancouver
Alıcıoğlu MB. Comparative Evaluation of the Load-Carrying Behavior of Fixed-End Steel Beams Using Different Analysis Methods. Süleyman Demirel Üniversitesi Fen Bilimleri Enstitüsü Dergisi. 2026;30(1):168-183. doi:10.19113/sdufenbed.1805609
BibTeX
@article{Alcolu2026,
author = {Alıcıoğlu, Mustafa Berker},
title = {Comparative Evaluation of the Load-Carrying Behavior of Fixed-End Steel Beams Using Different Analysis Methods},
journal = {Süleyman Demirel Üniversitesi Fen Bilimleri Enstitüsü Dergisi},
year = {2026},
volume = {30},
number = {1},
pages = {168--183},
doi = {10.19113/sdufenbed.1805609}
}
EUVIMED