Quality Improvement Project: Effectiveness of Diversion Tube Use on Blood Culture Contamination From Intravenous Catheters
Journal of Doctoral Nursing Practice · 11.05.2026 · JDNP-2025-0085.R1
DOI: 10.1891/jdnp-2025-0085 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Doctoral Nursing Practice, online erschienen am 11.05.2026. Verfasst von Anne Meginniss und 2 weiteren Autor:innen. Beteiligte Einrichtung: School of Nursing, University of New Hampshire, Durham, NH, USA anne.meginniss@unh.edu.
Abstract (Originalsprache)
Background
Contaminated blood cultures complicate medical decision-making, leading to unnecessary testing and treatment.
Objective
To evaluate the impact of an initial specimen diversion tube protocol on blood culture contamination rates in a community hospital emergency department.
Methods
Over 9 weeks, 27 blood culture specimens were obtained using a diversion tube at the time of intravenous insertion. Trained nursing superusers collected samples. Contamination rates were compared with those from the standard protocol.
Results
The standard protocol group demonstrated a 2.92% overall contamination rate (mean = 3.17%) with nine pathogens identified. The diversion protocol group showed a 3.70% overall contamination rate (mean = 2.38%) with only one pathogen isolated.
Conclusions
Although the standard protocol had a slightly lower overall contamination rate, the diversion protocol yielded fewer pathogens and a lower mean contamination rate, suggesting greater potential for sustainable contamination reduction.
Implications for Nursing
Nurse-driven interventions, including the use of diversion devices and superuser training, may enhance diagnostic accuracy and reduce unnecessary antibiotic exposure. Nursing engagement is essential to improving blood culture practices and sustaining quality outcomes.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- School of Nursing, University of New Hampshire, Durham, NH, USA anne.meginniss@unh.edu.
- School of Nursing, University of New Hampshire, Durham, NH, USA.
Zitieren
APA
Meginniss, A., Sharp, D., & Phelps, A. (2026). Quality Improvement Project: Effectiveness of Diversion Tube Use on Blood Culture Contamination From Intravenous Catheters. Journal of Doctoral Nursing Practice, JDNP-2025-0085.R1. https://doi.org/10.1891/jdnp-2025-0085
Vancouver
Meginniss A, Sharp D, Phelps A. Quality Improvement Project: Effectiveness of Diversion Tube Use on Blood Culture Contamination From Intravenous Catheters. Journal of Doctoral Nursing Practice. 2026:JDNP-2025-0085.R1. doi:10.1891/jdnp-2025-0085