EUVIMEDEUVIMED entdecken
Crossref

Quality Improvement Project: Effectiveness of Diversion Tube Use on Blood Culture Contamination From Intravenous Catheters

Anne Meginniss, Dayle Sharp, April Phelps

Journal of Doctoral Nursing Practice · 11.05.2026 · JDNP-2025-0085.R1

DOI: 10.1891/jdnp-2025-0085 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Doctoral Nursing Practice, online erschienen am 11.05.2026. Verfasst von Anne Meginniss und 2 weiteren Autor:innen. Beteiligte Einrichtung: School of Nursing, University of New Hampshire, Durham, NH, USA anne.meginniss@unh.edu.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Contaminated blood cultures complicate medical decision-making, leading to unnecessary testing and treatment.

Objective

To evaluate the impact of an initial specimen diversion tube protocol on blood culture contamination rates in a community hospital emergency department.

Methods

Over 9 weeks, 27 blood culture specimens were obtained using a diversion tube at the time of intravenous insertion. Trained nursing superusers collected samples. Contamination rates were compared with those from the standard protocol.

Results

The standard protocol group demonstrated a 2.92% overall contamination rate (mean = 3.17%) with nine pathogens identified. The diversion protocol group showed a 3.70% overall contamination rate (mean = 2.38%) with only one pathogen isolated.

Conclusions

Although the standard protocol had a slightly lower overall contamination rate, the diversion protocol yielded fewer pathogens and a lower mean contamination rate, suggesting greater potential for sustainable contamination reduction.

Implications for Nursing

Nurse-driven interventions, including the use of diversion devices and superuser training, may enhance diagnostic accuracy and reduce unnecessary antibiotic exposure. Nursing engagement is essential to improving blood culture practices and sustaining quality outcomes.

Schlagwörter

Stichwörter der Autor:innen

acute careblood culturecritical careemergency care

Autor:innen und Institutionen

  • School of Nursing, University of New Hampshire, Durham, NH, USA anne.meginniss@unh.edu.
  • School of Nursing, University of New Hampshire, Durham, NH, USA.

Zitieren

APA

Meginniss, A., Sharp, D., & Phelps, A. (2026). Quality Improvement Project: Effectiveness of Diversion Tube Use on Blood Culture Contamination From Intravenous Catheters. Journal of Doctoral Nursing Practice, JDNP-2025-0085.R1. https://doi.org/10.1891/jdnp-2025-0085

Vancouver

Meginniss A, Sharp D, Phelps A. Quality Improvement Project: Effectiveness of Diversion Tube Use on Blood Culture Contamination From Intravenous Catheters. Journal of Doctoral Nursing Practice. 2026:JDNP-2025-0085.R1. doi:10.1891/jdnp-2025-0085

BibTeX
@article{Meginniss2026,
  author = {Meginniss, Anne and Sharp, Dayle and Phelps, April},
  title = {Quality Improvement Project: Effectiveness of Diversion Tube Use on Blood Culture Contamination From Intravenous Catheters},
  journal = {Journal of Doctoral Nursing Practice},
  year = {2026},
  pages = {JDNP--2025--0085.R1},
  doi = {10.1891/jdnp-2025-0085}
}
Kostenlos starten →