DIAGNOSTIC ACCURACY OF APPARENT DIFFUSION COEFFICIENT FOR THE DIAGNOSIS OF ACUTE ARTERIAL STROKE KEEPING DIFFUSION WEIGHTED IMAGING AS GOLD STANDARD
Veredas do Direito · 09.04.2026 · 23 (6) · e5973
DOI: 10.18623/rvd.v23.5973 ↗Kurz gefasst
Fachartikel in der Zeitschrift Veredas do Direito, online erschienen am 09.04.2026. Verfasst von Hassan Rashid und 5 weiteren Autor:innen.
Themen: Schlaganfall
Abstract (Originalsprache)
Objective
To determine the diagnostic accuracy of apparent diffusion coefficient for diagnosis of acute arterial stroke taking diffusion weighted imaging as gold standard. Study Design Cross sectional validation study. Duration and Place of Study Conducted from December 2025 to March 2026 at Radiology Department, Ittefaq Hospital Trust, Lahore. Methodology A total of 166 patients aged 30–70 years with clinical diagnosis of acute arterial stroke were included. Magnetic resonance imaging was performed and apparent diffusion coefficient and diffusion weighted imaging findings were recorded. Mean and standard deviation was calculated for quantitative variables while frequency and percentage were used for qualitative variables. Diagnostic accuracy parameters including sensitivity, specificity, positive predictive value and negative predictive value was calculated by 2×2 table.
Results
Mean age was 53.89 ± 8.52 years and mean body mass index was 28.11 ± 3.12 kg/m². Males were 53.6% and females 46.4%. Apparent diffusion coefficient showed sensitivity 70%, specificity 80% and overall diagnostic accuracy 73%. Positive predictive value was 86% while negative predictive value was 59%.
Conclusion
Apparent diffusion coefficient is moderately accurate for diagnosis of acute arterial stroke but cannot be used alone as compared to diffusion weighted imaging.
Zitieren
APA
Rashid, H., Babri, M. A., Mazhar, M., Talat, U., Imran, S., & Imran, I. (2026). DIAGNOSTIC ACCURACY OF APPARENT DIFFUSION COEFFICIENT FOR THE DIAGNOSIS OF ACUTE ARTERIAL STROKE KEEPING DIFFUSION WEIGHTED IMAGING AS GOLD STANDARD. Veredas do Direito, 23(6), e5973. https://doi.org/10.18623/rvd.v23.5973
Vancouver
Rashid H, Babri MA, Mazhar M, Talat U, Imran S, Imran I. DIAGNOSTIC ACCURACY OF APPARENT DIFFUSION COEFFICIENT FOR THE DIAGNOSIS OF ACUTE ARTERIAL STROKE KEEPING DIFFUSION WEIGHTED IMAGING AS GOLD STANDARD. Veredas do Direito. 2026;23(6):e5973. doi:10.18623/rvd.v23.5973
BibTeX
@article{Rashid2026,
author = {Rashid, Hassan and Babri, Mohammad Aqeel and Mazhar, Momin and Talat, Ushna and Imran, Somia and Imran, Izza},
title = {DIAGNOSTIC ACCURACY OF APPARENT DIFFUSION COEFFICIENT FOR THE DIAGNOSIS OF ACUTE ARTERIAL STROKE KEEPING DIFFUSION WEIGHTED IMAGING AS GOLD STANDARD},