Development of PANI–CNT Coated Fabric-Based Flexible Electrodes for Electromyography (EMG) Measurement
International Journal on Advanced Science, Engineering and Information Technology · 25.10.2026 · 16 (5) · 1936-1943
DOI: 10.18517/ijaseit.16.5.22036 ↗Kurz gefasst
Fachartikel in der Zeitschrift International Journal on Advanced Science, Engineering and Information Technology, online erschienen am 25.10.2026. Verfasst von Aulia Ghifari Nurlis und 4 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Electromyography (EMG) is a technique used to measure biopotential signals generated by muscle activity. EMG electrodes are generally classified into wet and dry electrodes. Wet electrodes require an electrolyte gel, which may cause skin irritation during prolonged use. In contrast, conventional dry electrodes often exhibit poor skin contact, resulting in reduced signal quality. Therefore, the development of flexible electrodes capable of producing reliable EMG signals is highly desirable. This study investigates the fabrication and performance of flexible fabric-based electrodes using polyaniline (PANI) and multi-walled carbon nanotubes (MWCNT) as conductive materials through the Chemical Oxidation Polymerization (COP) method. Several electrode variations were prepared, including PANI + MWCNT, PANI + functionalized MWCNT (FMWCNT), and PANI + MWCNT + FMWCNT, to evaluate the influence of CNT incorporation on electrode properties. The fabricated electrodes were characterized for physicochemical properties, electrical conductivity, and EMG signal acquisition performance. The results indicate that the electrode containing PANI, MWCNT, and FMWCNT exhibited the best EMG signal detection capability. The PANI + MWCNT + FMWCNT electrode achieved the highest SNR among the developed flexible electrodes (33.76 dB), compared with 27.28 dB for PANI + MWCNT and 22.81 dB for PANI + FMWCNT. Under identical experimental conditions, the commercial Ag/AgCl electrode exhibited an SNR of 42.71 dB, indicating that further optimization is required for the developed flexible electrode to approach the signal quality of the conventional electrode. Future research may focus on improving the long-term stability of the electrodes and on evaluating their performance in real-time wearable health-monitoring applications.
Zitieren
APA
Nurlis, A. G., Adhika, D. R., Suprijanto, Shidqi, M. H., & Zahrani, R. N. (2026). Development of PANI–CNT Coated Fabric-Based Flexible Electrodes for Electromyography (EMG) Measurement. International Journal on Advanced Science, Engineering and Information Technology, 16(5), 1936-1943. https://doi.org/10.18517/ijaseit.16.5.22036
Vancouver
Nurlis AG, Adhika DR, Suprijanto, Shidqi MH, Zahrani RN. Development of PANI–CNT Coated Fabric-Based Flexible Electrodes for Electromyography (EMG) Measurement. International Journal on Advanced Science, Engineering and Information Technology. 2026;16(5):1936-1943. doi:10.18517/ijaseit.16.5.22036
BibTeX
@article{Nurlis2026,
author = {Nurlis, Aulia Ghifari and Adhika, Damar Rastri and Suprijanto and Shidqi, Muhammad Hafizh and Zahrani, Raisa Nurul},
title = {Development of PANI–CNT Coated Fabric-Based Flexible Electrodes for Electromyography (EMG) Measurement},
journal = {International Journal on Advanced Science, Engineering and Information Technology},
year = {2026},
volume = {16},
number = {5},
pages = {1936--1943},
doi = {10.18517/ijaseit.16.5.22036}
}