Functional Outcome of Arthroscopic Bankart Repair with Knotless Suture Anchor: A Retrospective Observational Study
Journal of Orthopedic and Spine Trauma · 2024
DOI: 10.18502/jost.v10i2.15513 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Orthopedic and Spine Trauma, 2024. Verfasst von Ravindra Chauhan und 4 weiteren Autor:innen.
Abstract (Originalsprache)
Background
The soft tissue in the shoulder plays a significant role in anterior shoulder instability, leading to humeral head displacement from the glenoid fossa. Arthroscopic Bankart repair is a widely accepted method to restore the labrum to the joint rim. This study aims to evaluate the clinical outcomes of Bankart repair by knotless suture anchors at medium-term follow-up, assess the functional outcomes of the knotless suture anchor method for recurrent anterior glenohumeral instability, and conduct clinical assessment using the Rowe score at 6-week, 3-month, 6-month, and 12-month intervals in patients.
Methods
In this retrospective study, patients who underwent arthroscopic Bankart repair using a 2.8 mm knotless suture anchor (MINI-VIM PK® ) were enrolled. They were assessed for shoulder stability, range of motion (ROM), and functional outcomes using the Rowe scale at the baseline, 6-week, 3-month, 6-month, and 12-month follow-up intervals as part of the planned early efficacy measures. All the statistical analyses were performed using SPSS software.
Results
The mean age of the subjects was 28.10 ± 6.14. In this trial, 51 patients (69.86%) were diagnosed with recurrent shoulder dislocation on the left side, and 22 patients (30.14%) on the right side. The Rowe score demonstrated a significant improvement (P < 0.0001), increasing from 44.73 ± 1.64 to 95.62 ± 18.33 at the 12-month follow-up period. This indicated better clinical outcomes and reduced recurrence of instability with the use of knotless suture anchors.
Conclusion
The use of knotless suture anchors demonstrated reduced recurrence rates, improved post-operative shoulder motion, and increased stability without adding complexity to the procedure.
Zitieren
APA
Chauhan, R., Pande, A., Shaktawat, D. S., Dwivedi, A., & Thomas, S. (2024). Functional Outcome of Arthroscopic Bankart Repair with Knotless Suture Anchor: A Retrospective Observational Study. Journal of Orthopedic and Spine Trauma. https://doi.org/10.18502/jost.v10i2.15513
Vancouver
Chauhan R, Pande A, Shaktawat DS, Dwivedi A, Thomas S. Functional Outcome of Arthroscopic Bankart Repair with Knotless Suture Anchor: A Retrospective Observational Study. Journal of Orthopedic and Spine Trauma. 2024. doi:10.18502/jost.v10i2.15513
BibTeX
@article{Chauhan2024,
author = {Chauhan, Ravindra and Pande, Ashish and Shaktawat, Dilip Singh and Dwivedi, Aditya and Thomas, Shijo},
title = {Functional Outcome of Arthroscopic Bankart Repair with Knotless Suture Anchor: A Retrospective Observational Study},
journal = {Journal of Orthopedic and Spine Trauma},
year = {2024},
doi = {10.18502/jost.v10i2.15513}
}
EUVIMED