Impact of Image Reconstruction on Quantitative Analysis of 18F-FDG PET in Epilepsy Evaluation: A Preliminary Study
Frontiers in Biomedical Technologies · 29.06.2026
DOI: 10.18502/fbt.v13i2.21944 ↗Kurz gefasst
Fachartikel in der Zeitschrift Frontiers in Biomedical Technologies, online erschienen am 29.06.2026. Verfasst von Naghmeh Firouzi und 4 weiteren Autor:innen.
Abstract (Originalsprache)
Purpose
In epilepsy pre-surgical evaluations, semi-automated quantitative analysis of Fluorine-18-fluorodeoxyglucose (¹⁸F-FDG) brain PET complements visual assessment for localizing the seizure onset zone. This study evaluates how adjusting reconstruction parameters enhances quantitative accuracy, aiming to identify optimal configurations for reliable clinical decision-making. Materials and Methods: 234 reconstruction methods were applied to 18F-FDG brain PET images of a 47-year-old male with focal epilepsy. The parameters encompassed the 3D-Ordered-Subset Expectation Maximization image reconstruction method, both with Resolution Recovery (RR) and without (non-RR), various numbers of iterations×subset (#it×sub), pixel sizes, and Gaussian filters. The accuracy errors were determined by the Relative Difference Percentage (RDP) in measured maximum standardized uptake value SUVmax and absolute Z-scores from all 234 reconstructed images, compared to reference values from the normal database reconstruction set as the benchmark Results: The study revealed that reconstructed images with 5 mm or 8 mm full width at half maximum (FWHM) Gaussian filters yielded RDP values above 5% for SUVmax and Z-scores, indicating potential inaccuracy with higher values of post-smoothing filters. The recommended reconstruction sets with RDP values below 5% for both RR and non-RR images were those with a 3 mm FWHM Gaussian filter and higher (#it×sub), specifically (5×21, 8×21), (5×21, 6×21), and (7×21, 8×21) for pixel sizes of 1.01 mm, 1.35 mm, and 2.03 mm, respectively.
Conclusion
The findings underscore the significant impact of altering the image reconstruction sets on the SUVmax and Z-scores. Furthermore, the inconsistent fluctuations of Z-scores emphasize the importance of using standardized image reconstruction sets to ensure accurate and reliable quantitative outcomes in epilepsy pre-surgical evaluations.
Zitieren
APA
Firouzi, N., Parach, A. A., Tanha, K., Rostami, M. S., & Geramifar, P. (2026). Impact of Image Reconstruction on Quantitative Analysis of 18F-FDG PET in Epilepsy Evaluation: A Preliminary Study. Frontiers in Biomedical Technologies. https://doi.org/10.18502/fbt.v13i2.21944
Vancouver
Firouzi N, Parach AA, Tanha K, Rostami MS, Geramifar P. Impact of Image Reconstruction on Quantitative Analysis of 18F-FDG PET in Epilepsy Evaluation: A Preliminary Study. Frontiers in Biomedical Technologies. 2026. doi:10.18502/fbt.v13i2.21944
BibTeX
@article{Firouzi2026,
author = {Firouzi, Naghmeh and Parach, Ali Asghar and Tanha, Kaveh and Rostami, Mohammad Sadegh and Geramifar, Parham},
title = {Impact of Image Reconstruction on Quantitative Analysis of 18F-FDG PET in Epilepsy Evaluation: A Preliminary Study},
journal = {Frontiers in Biomedical Technologies},
year = {2026},
doi = {10.18502/fbt.v13i2.21944}
}
EUVIMED