EUVIMEDEUVIMED entdecken
Crossref

A comparative evaluation of design factors on bubble column operation in photosynthetic biogas upgrading

Archishman Bose, Richard O’Shea, Richen Lin, Jerry D. Murphy

Biofuel Research Journal · 01.06.2021 · 8 (2) · 1351-1373

DOI: 10.18331/brj2021.8.2.2 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biofuel Research Journal, online erschienen am 01.06.2021. Verfasst von Archishman Bose und 3 weiteren Autor:innen. Die Arbeit wurde bisher 25-mal zitiert (Crossref).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Studies attempting to optimise photosynthetic biogas upgrading by simultaneous investigation of the bubble column-photobioreactor setup have experienced considerable variability in results and conclusions. To identify the sources of such variation, this work quantitatively compared seven design factors (superficial gas velocity; liquid to gas flow rate (L/G) ratio; empty bed residence time; liquid inlet pH; liquid inlet alkalinity; temperature; and algal concentration) using the L16 Taguchi orthogonal array as a screening design of experiment. Assessments were performed using the signal to noise (S/N) ratio on the performance of CO2 removal (CO­2 removal efficiency, CO2 absorption rate, and overall CO2 mass transfer coefficient) and O2 stripping (O2 concentration in biomethane and O2 flow rate in biomethane). Results showed that pH and L/G ratio were the most critical design factors. Temperature and gas residence times had minimal impact on the biomethane composition. The interactive effect between pH and L/G ratio was the most impactful, followed by the interactive effects between superficial gas velocity and L/G ratio and pH on CO2 removal efficiency. The impact of L/G ratio, algal concentration, and pH (in that order of impact) caused up to a 90% variation in oxygen content in biomethane. However, algal concentration had a diminishing role as the L/G ratio increased. Using only the statistically significant main effects and interactions, the biomethane composition (CO2% and O2%) was predicted with over 95% confidence through regression equations for superficial gas velocity up to 0.2 cm/s.

Zitieren

APA

Bose, A., O’Shea, R., Lin, R., & Murphy, J. D. (2021). A comparative evaluation of design factors on bubble column operation in photosynthetic biogas upgrading. Biofuel Research Journal, 8(2), 1351-1373. https://doi.org/10.18331/brj2021.8.2.2

Vancouver

Bose A, O’Shea R, Lin R, Murphy JD. A comparative evaluation of design factors on bubble column operation in photosynthetic biogas upgrading. Biofuel Research Journal. 2021;8(2):1351-1373. doi:10.18331/brj2021.8.2.2

BibTeX
@article{Bose2021,
  author = {Bose, Archishman and O’Shea, Richard and Lin, Richen and Murphy, Jerry D.},
  title = {A comparative evaluation of design factors on bubble column operation in photosynthetic biogas upgrading},
  journal = {Biofuel Research Journal},
  year = {2021},
  volume = {8},
  number = {2},
  pages = {1351--1373},
  doi = {10.18331/brj2021.8.2.2}
}
Kostenlos starten →