Assessment of HC-290 Charge Reduction in Split Type Air Conditioner
Journal of Mines, Metals and Fuels · 15.04.2026 · 361-373
DOI: 10.18311/jmmf/2026/53232 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Mines, Metals and Fuels, online erschienen am 15.04.2026. Verfasst von Heramb C. Phadake und 1 weiteren Autor:innen. Die Arbeit nennt 16 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).
Abstract (Originalsprache)
Global warming and measures to avoid it are at the forefront globally to drive and develop reasons to avoid climate change. Kyoto protocol guides air conditioning sector to avoid use of HFCs by adopting an alternative refrigerant. HC-290, a potential alternative refrigerant, possesses negligible ozone depletion potential (ODP) and a minimal global warming potential (GWP). However, it is highly flammable refrigerant imposing limitation on the charge quantity that can be used in the Split air conditioner (SAC). Present study describes Vapor compression cycle (VCC) analysis for the refrigerant charge reduction by variation of some of the geometric parameters for the condenser and it also describes possible ways to reduce charge by variation to some other system parameters of SAC. To establish base lines, results of a standard SAC with HC-290 refrigerant, tested under psychometric test chamber are used. The cooling capacity of 5.1 kW and EER of 3.85 % are recorded for the base line SAC. Parametric study to identify the most impacting parameters to reduce charge without reducing the cooling capacity and Energy efficiency ratio (EER) of the air conditioner is done. Condenser carries maximum charge in the entire VCC so modifications are done to the condenser. A vertical tube condenser is mathematically designed to achieve the same cooling capacity and EER. The simulation model is developed by maintaining the same cooling capacity and EER. The charge reported on the base line SAC is 330 gms. By modification in the condenser, 24% refrigerant charge reduction is observed. Global warming is at the forefront to drive and develop method or equipment to avoid climate change. Kyoto protocol guides air conditioning sector to avoid use of HFCs by adopting an alternative refrigerant. HC-290, a potential alternative refrigerant, possesses negligible Ozone Depletion Potential (ODP) and a minimal Global Warming Potential (GWP). However, it is highly flammable refrigerant imposing limitation on the charge quantity that can be used in the Split Air Conditioner (SAC). Present study describes Vapor Compression Cycle (VCC) analysis for the refrigerant charge reduction by variation of some of the geometric parameters for the condenser and it also describes possible ways to reduce charge by variation to condenser without change in system process parameters of SAC. By optimizing condenser design through parametric analysis and simulation, this work explores refrigerant charge reduction in an HC-290 split air conditioner. A mathematically designed vertical tube condenser was used, and the system maintained a cooling capacity of 5100 kW and an EER of 3.85% while achieving a 24% reduction from the baseline 330g charge. The main cause of charge decrease, according to the findings, is condenser change, while expansion device sizing also affects the overall charge mass. Major Findings: By vertical tube condenser it is possible to save refrigerant charge in SAC. There is no impact on the cooling capacity and EER for the similar capacity of SAC.
Zitieren
APA
Phadake, H. C., & Mali, K. V. (2026). Assessment of HC-290 Charge Reduction in Split Type Air Conditioner. Journal of Mines, Metals and Fuels, 361-373. https://doi.org/10.18311/jmmf/2026/53232
Vancouver
Phadake HC, Mali KV. Assessment of HC-290 Charge Reduction in Split Type Air Conditioner. Journal of Mines, Metals and Fuels. 2026:361-373. doi:10.18311/jmmf/2026/53232
BibTeX
@article{Phadake2026,
author = {Phadake, Heramb C. and Mali, Kundlik V.},
title = {Assessment of HC-290 Charge Reduction in Split Type Air Conditioner},
journal = {Journal of Mines, Metals and Fuels},
year = {2026},
pages = {361--373},
doi = {10.18311/jmmf/2026/53232}
}
EUVIMED