EUVIMEDEUVIMED entdecken
Open Access

Modular surgical approach for angle-closure glaucoma secondary to nanophthalmos

Yan Gao, Xiao-Wei Yu, Lin Deng, Feng Mei, Miao Zhang, Hong-Yu Zhong, Tian-Rui Zhang, Yan Shi, Zhi-Gang Fan

International Journal of Ophthalmology · 18.04.2026 · 19 (4) · 709-719

DOI: 10.18240/ijo.2026.04.10 ↗

Kurz gefasst

Fachartikel in der Zeitschrift International Journal of Ophthalmology, erschienen am 18.04.2026. Verfasst von Yan Gao und 8 weiteren Autor:innen. Beteiligte Einrichtung: Beijing Tongren Eye Center Research Ward, Beijing Tongren Hospital, Beijing Institute of Ophthalmology, Beijing Ophthalmology & Visual Sciences Key L…. Die Arbeit wurde bisher 2-mal zitiert (Crossref). Der Volltext ist frei in PubMed Central verfügbar.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

AIM: To explore and summarize outcomes of a modular surgical approach for the personalized management of angle-closure glaucoma (ACG) secondary to nanophthalmos. METHODS: This was a retrospective interventional case series involving consecutive patients with nanophthalmos and ACG. All patients were treated with a modular surgical approach tailored to their specific disease characteristics, which included the following surgical combinations: Procedure I [phacoemulsification (phaco)+goniosynechialysis (GSL)], Procedure II [Procedure I +irido-zonulo-hyaloid-vitrectomy (IZHV)], Procedure III [phaco +IZHV+Ahmed glaucoma valve (AGV) implantation], and Procedure IV (Procedure III+scleral window creation). RESULTS: A total of 92 eyes from 62 patients were enrolled, with a median age of 52 (range: 23-72)y and a median axial length of 19.89 (range: 14.84-20.99) mm. According to the patients’ distinct clinical characteristics, 14, 26, 22, and 30 eyes underwent Procedures I, II, III, and IV, respectively. The median follow-up duration was 13 (range: 12-36)mo. At the final follow-up visit, all patients achieved a sustained intraocular pressure (IOP) below 21 mm Hg without the administration of anti-glaucoma medications. Postoperative complications included malignant glaucoma (MG, 9 eyes), uveal effusion (UE, 5 eyes), suprachoroidal hemorrhage (1 eye), fibrin membrane formation (4 eyes), uveitis (1 eye), macular edema (1 eye), and impaired corrected distance visual acuity (CDVA, 6 eyes). Univariate analysis revealed that younger age was associated with a higher risk of MG (OR: 1.06, P=0.04), UE (OR: 1.07, P=0.046), and impaired CDVA (OR: 1.11, P=0.02). CONCLUSION: The modular surgical approach yields favorable and consistent clinical prognoses, while reducing the incidence of complications, in the challenging clinical scenario of ACG secondary to nanophthalmos.

Schlagwörter

Stichwörter der Autor:innen

angle-closure glaucomairido-zonulo-hyaloid-vitrectomymalignant glaucomananophthalmosuveal effusion

Autor:innen und Institutionen

  • Beijing Tongren Eye Center Research Ward, Beijing Tongren Hospital, Beijing Institute of Ophthalmology, Beijing Ophthalmology & Visual Sciences Key Laboratory, Capital Medical University, Beijing 100730, China.

Zitieren

APA

Gao, Y., Yu, X. W., Deng, L., Mei, F., Zhang, M., Zhong, H. Y., Zhang, T. R., Shi, Y., & Fan, Z. G. (2026). Modular surgical approach for angle-closure glaucoma secondary to nanophthalmos. International Journal of Ophthalmology, 19(4), 709-719. https://doi.org/10.18240/ijo.2026.04.10

Vancouver

Gao Y, Yu XW, Deng L, Mei F, Zhang M, Zhong HY, et al. Modular surgical approach for angle-closure glaucoma secondary to nanophthalmos. International Journal of Ophthalmology. 2026;19(4):709-719. doi:10.18240/ijo.2026.04.10

BibTeX
@article{Gao2026,
  author = {Gao, Yan and Yu, Xiao-Wei and Deng, Lin and Mei, Feng and Zhang, Miao and Zhong, Hong-Yu and Zhang, Tian-Rui and Shi, Yan and Fan, Zhi-Gang},
  title = {Modular surgical approach for angle-closure glaucoma secondary to nanophthalmos},
  journal = {International Journal of Ophthalmology},
  year = {2026},
  volume = {19},
  number = {4},
  pages = {709--719},
  doi = {10.18240/ijo.2026.04.10}
}
Kostenlos starten →