EUVIMEDEUVIMED entdecken
Open Access

Sulcus fixation of a standard capsular tension ring in cataract surgery with capsular instability

Kyu Sang Eah, Hayoung Lee, Yoo Young Jeon, Ho Seok Chung, Hun Lee, Jae Yong Kim

International Journal of Ophthalmology · 18.04.2026 · 19 (4) · 696-700

DOI: 10.18240/ijo.2026.04.08 ↗

Kurz gefasst

Fachartikel in der Zeitschrift International Journal of Ophthalmology, erschienen am 18.04.2026. Verfasst von Kyu Sang Eah und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Ophthalmology, Asan Medical Center, University of Ulsan College of Medicine, Seoul 05505, Republic of Korea. Der Volltext ist frei in PubMed Central verfügbar.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

AIM: To introduce a novel technique for stabilizing the capsular bag in cataract surgery. METHODS: This retrospective observational case series included eyes with unstable capsular bag that underwent cataract surgery. A standard capsular tension ring (CTR) with 10-0 Prolene sutures was inserted into the capsular bag and fixated to the sulcus to stabilize the bag, enabling in-the-bag intraocular lens (IOL) implantation. Uncorrected distance visual acuity, corrected distance visual acuity (CDVA), and slit-lamp examination were performed preoperatively and at 1 and 6mo postoperatively. RESULTS: Of the 17 eyes from 15 patients (mean age 51.20±19.60y, male/female=11/6), 8 had subluxation due to Marfan syndrome, 3 due to trauma, 5 due to zonular weakness, and 1 due to acute angle closure glaucoma. The preoperative mean CDVA (logMAR) was 0.56±0.67 (mean spherical equivalent: −6.39±4.78 D). At 1mo postoperatively, the mean CDVA improved to 0.21±0.37 (mean spherical equivalent: −0.35±1.07 D). At 6mo, the mean CDVA was 0.32±0.39, and the mean spherical equivalent was −0.34±0.99 D. All patients showed significant visual improvement at both postoperative visits (P

Schlagwörter

Stichwörter der Autor:innen

capsular tension ringcataractintraocular lens implantationsulcus fixationzonulysis

Autor:innen und Institutionen

  • Department of Ophthalmology, Asan Medical Center, University of Ulsan College of Medicine, Seoul 05505, Republic of Korea.

Zitieren

APA

Eah, K. S., Lee, H., Jeon, Y. Y., Chung, H. S., Lee, H., & Kim, J. Y. (2026). Sulcus fixation of a standard capsular tension ring in cataract surgery with capsular instability. International Journal of Ophthalmology, 19(4), 696-700. https://doi.org/10.18240/ijo.2026.04.08

Vancouver

Eah KS, Lee H, Jeon YY, Chung HS, Lee H, Kim JY. Sulcus fixation of a standard capsular tension ring in cataract surgery with capsular instability. International Journal of Ophthalmology. 2026;19(4):696-700. doi:10.18240/ijo.2026.04.08

BibTeX
@article{Eah2026,
  author = {Eah, Kyu Sang and Lee, Hayoung and Jeon, Yoo Young and Chung, Ho Seok and Lee, Hun and Kim, Jae Yong},
  title = {Sulcus fixation of a standard capsular tension ring in cataract surgery with capsular instability},
  journal = {International Journal of Ophthalmology},
  year = {2026},
  volume = {19},
  number = {4},
  pages = {696--700},
  doi = {10.18240/ijo.2026.04.08}
}
Kostenlos starten →