EUVIMEDEUVIMED entdecken
Open Access

Tomographic and biomechanical corneal characteristics of patients with angioid streaks

Gökhan Gürelik, Betül Seher Uysal, Merve Nur Şahin, Hüseyin Baran Özdemir, Kamil Bilgihan

International Journal of Ophthalmology · 18.04.2026 · 19 (4) · 688-695

DOI: 10.18240/ijo.2026.04.07 ↗

Kurz gefasst

Fachartikel in der Zeitschrift International Journal of Ophthalmology, erschienen am 18.04.2026. Verfasst von Gökhan Gürelik und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Ophthalmology, Gazi University Faculty of Medicine, Ankara 06500, Türkiye. Der Volltext ist frei in PubMed Central verfügbar.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

AIM: To evaluate the corneal biomechanical properties in patients with angioid streaks (AS), and to compare these parameters with those of healthy subjects. METHODS: A retrospective study was conducted, enrolling AS patients and healthy participants as controls. The collected corneal tomographic parameters included flat keratometry, steep keratometry, mean keratometry, maximum keratometry, topographic cylinder value, central corneal thickness, and the total deviation value of the Belin-Ambrósio enhanced ectasia display measured with Pentacam tomography. Corvis ST was used to measure corneal biomechanical parameters, non-contact tonometry intraocular pressure (IOPnct), and biomechanically corrected intraocular pressure (bIOP). RESULTS: The study comprised 18 eyes from 10 male and 8 female AS patients with a mean age of 48.83±10.66y, and the controls included 31 eyes from 12 male and 19 female healthy participants with a mean age of 47.87±10.69y. All corneal tomographic parameters were comparable between the two groups (all P>0.05), and no corneal ectasia was observed in any AS patient. Compared with the controls, AS patients exhibited statistically significant increases in applanation 1 (A1) time and stiffness parameter A1 (SP-A1), along with significant decreases in applanation 2 (A2) velocity, deformation amplitude (DA), DA ratio (2 mm), and Corvis biomechanical index (CBI; all P

Schlagwörter

Stichwörter der Autor:innen

angioid streakscorneal biomechanicscorneal tomographyintraocular pressure

Autor:innen und Institutionen

  • Department of Ophthalmology, Gazi University Faculty of Medicine, Ankara 06500, Türkiye.
  • Pursaklar State Hospital, Ankara 06145, Türkiye.

Zitieren

APA

Gürelik, G., Uysal, B. S., Şahin, M. N., Özdemir, H. B., & Bilgihan, K. (2026). Tomographic and biomechanical corneal characteristics of patients with angioid streaks. International Journal of Ophthalmology, 19(4), 688-695. https://doi.org/10.18240/ijo.2026.04.07

Vancouver

Gürelik G, Uysal BS, Şahin MN, Özdemir HB, Bilgihan K. Tomographic and biomechanical corneal characteristics of patients with angioid streaks. International Journal of Ophthalmology. 2026;19(4):688-695. doi:10.18240/ijo.2026.04.07

BibTeX
@article{Grelik2026,
  author = {Gürelik, Gökhan and Uysal, Betül Seher and Şahin, Merve Nur and Özdemir, Hüseyin Baran and Bilgihan, Kamil},
  title = {Tomographic and biomechanical corneal characteristics of patients with angioid streaks},
  journal = {International Journal of Ophthalmology},
  year = {2026},
  volume = {19},
  number = {4},
  pages = {688--695},
  doi = {10.18240/ijo.2026.04.07}
}
Kostenlos starten →