EUVIMEDEUVIMED entdecken
Crossref

Segmentation and Measurement of Carotid Artery Stenosis in Ultrasound Images Using Computer Vision Methods

Elçin Bilici, Mete Yağanoğlu

Erzincan Üniversitesi Fen Bilimleri Enstitüsü Dergisi · 30.03.2026 · 19 (1) · 379-394

DOI: 10.18185/erzifbed.1738617 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Erzincan Üniversitesi Fen Bilimleri Enstitüsü Dergisi, online erschienen am 30.03.2026. Verfasst von Elçin Bilici und 1 weiteren Autor:innen. Die Arbeit nennt 31 Literaturangaben.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

With the change of living conditions and dietary habits, there has been an increase in vascular diseases in recent years. These diseases often lead to peripheral narrowing and occlusion of the arteries. In the management of vascular diseases, which can lead to serious consequences such as stroke and even death, it is very valuable to use appropriate imaging techniques for early and accurate diagnosis. However, the large and complex vascular network makes it difficult to analyze accurate data during diagnostic procedures. In our study, we aimed to easily, quickly and effectively recognize carotid arteries and stenoses ultrasonographically using computer vision deep learning techniques. A dataset containing 3 different levels of the carotid artery was created by obtaining 3401 US images from 120 cases whose age and gender were randomly selected. The width of the carotid artery and the vessels where stenosis was detected were measured using the computer vision deep learning method. Computer vision deep learning segmentation successfully detected carotid arteries with a rate of 98% and stenosis in the carotid artery with a rate of 90%, which is considered high.

Zitieren

APA

Bilici, E., & Yağanoğlu, M. (2026). Segmentation and Measurement of Carotid Artery Stenosis in Ultrasound Images Using Computer Vision Methods. Erzincan Üniversitesi Fen Bilimleri Enstitüsü Dergisi, 19(1), 379-394. https://doi.org/10.18185/erzifbed.1738617

Vancouver

Bilici E, Yağanoğlu M. Segmentation and Measurement of Carotid Artery Stenosis in Ultrasound Images Using Computer Vision Methods. Erzincan Üniversitesi Fen Bilimleri Enstitüsü Dergisi. 2026;19(1):379-394. doi:10.18185/erzifbed.1738617

BibTeX
@article{Bilici2026,
  author = {Bilici, Elçin and Yağanoğlu, Mete},
  title = {Segmentation and Measurement of Carotid Artery Stenosis in Ultrasound Images Using Computer Vision Methods},
  journal = {Erzincan Üniversitesi Fen Bilimleri Enstitüsü Dergisi},
  year = {2026},
  volume = {19},
  number = {1},
  pages = {379--394},
  doi = {10.18185/erzifbed.1738617}
}
Kostenlos starten →