Three-dimensional technologies for personalized external breast prostheses: a comparative user evaluation after unilateral mastectomy
Medical Research Archives · 31.08.2026 · 14 (8)
DOI: 10.18103/mra.2026.0545 ↗Kurz gefasst
Fachartikel in der Zeitschrift Medical Research Archives, online erschienen am 31.08.2026. Verfasst von Mariana Pohlmann de Oliveira und 2 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Background
Commercial external breast prostheses are commonly used after mastectomy, but standardized models may not accommodate individual anatomical characteristics, affecting comfort, stability, and appearance. Three-dimensional technologies enable anatomical personalization; however, technical feasibility does not necessarily ensure a satisfactory user experience.
Aims
To compare the experiences of women after unilateral mastectomy using personalized external breast prostheses and their routinely used commercial prostheses.
Methods
This exploratory comparative study combined quantitative ratings and qualitative observations. Fourteen women who had undergone unilateral mastectomy without reconstruction completed a preliminary interview about prosthesis use and satisfaction. Five participants reporting neutral or negative overall satisfaction were selected for personalization. Individualized models were developed from three-dimensional scans of the remaining breast and mastectomy region. Three participants completed the final evaluation, wearing each prosthesis for 20 minutes and performing standardized body movements. Comfort, thermal sensation, stability, anatomical accommodation, weight, shape, size, and overall satisfaction were evaluated using five-point Likert-scale questions and qualitative observations.
Results
All three participants rated the posterior fit of the personalized prostheses positively but rated their commercial prostheses negatively for this attribute. The weight of the personalized models was also positively evaluated by all participants. Two reported increased overall satisfaction with the personalized prosthesis, whereas one maintained a neutral assessment. No consistent differences were observed in incision discomfort or thermal sensation. Perceptions of external shape and size varied. Qualitative observations identified excessive lateral volume, anterior projection, interference with arm movements, and instability during forward trunk flexion as aspects requiring refinement.
Conclusion
Anatomical personalization may improve chest-wall accommodation and user satisfaction. Nevertheless, anatomical correspondence alone does not ensure overall suitability. User evaluation should guide the refinement of external geometry, physical properties, stability, and interaction with the body during movement.
Zitieren
APA
Oliveira, M. P. D., Fonte, R. S. D., & Silva, F. P. D. (2026). Three-dimensional technologies for personalized external breast prostheses: a comparative user evaluation after unilateral mastectomy. Medical Research Archives, 14(8). https://doi.org/10.18103/mra.2026.0545
Vancouver
Oliveira MPD, Fonte RSD, Silva FPD. Three-dimensional technologies for personalized external breast prostheses: a comparative user evaluation after unilateral mastectomy. Medical Research Archives. 2026;14(8). doi:10.18103/mra.2026.0545
BibTeX
@article{Oliveira2026,
author = {Oliveira, Mariana Pohlmann de and Fonte, Raquel Sudbrack da and Silva, Fabio Pinto da},
title = {Three-dimensional technologies for personalized external breast prostheses: a comparative user evaluation after unilateral mastectomy},
journal = {Medical Research Archives},
year = {2026},
volume = {14},
number = {8},
doi = {10.18103/mra.2026.0545}
}
EUVIMED