Impact of Region of Interest Size on Semi-Quantification of Myocardial 99mTc-pyrophosphate Uptake in Suspected Transthyretin Cardiac Amyloidosis
Annals of Nuclear Cardiology · 2025 · 11 (1) · 33-38
DOI: 10.17996/anc.25-00005 ↗Kurz gefasst
Fachartikel in der Zeitschrift Annals of Nuclear Cardiology, 2025. Verfasst von Toshinori Saitou und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, Hokkaido Cardiovascular Hospital, Hokkaido, Japan. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 15 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.
Abstract (Originalsprache)
Background
This study aimed to evaluate the optimal region of interest (ROI) size of the heart-to-contralateral (H/CL) ratio on planar imaging for detecting myocardial technetium-99m pyrophosphate (PYP) uptake in patients with suspected transthyretin cardiac amyloidosis (ATTR-CA) and to assess the impact of ROI size on intra- and interobserver variability in the H/CL ratio.
Methods
We retrospectively analyzed 90 consecutive patients who underwent PYP imaging for ATTR-CA evaluation after excluding 20 patients without myocardial PYP uptake on planar images (i.e., Grade 0). The H/CL ratio was measured using three ROI sizes (4.5 cm, 3 cm, and 2 cm). Receiver operating characteristic (ROC) analysis was used to evaluate the performance of each ROI size in detecting positive PYP single-photon emission computed tomography (SPECT). Intra- and inter-observer variability was assessed using intraclass correlation coefficients (ICCs).
Results
Grade 2-3 myocardial PYP uptake on SPECT was observed in 41 (46%) patients. ROC analysis revealed no significant differences in the area under the curve among the various ROI sizes at 1 hour (0.68, 0.71, and 0.71 for the 4.5-, 3-, and 2-cm ROIs, respectively; P=0.44) or 3 hours (0.71, 0.72, and 0.72 for the 4.5-, 3-, and 2-cm ROIs, respectively; P=0.86). The largest ROI (4.5 cm) demonstrated the highest reproducibility, with excellent intra-observer (ICC=0.949) and inter-observer (ICC=0.906) agreement.
Conclusions
The size of the ROI used to calculate the H/CL ratio did not significantly affect the detection of myocardial PYP uptake in patients with suspected ATTR-CA. Using a larger ROI size that covers the entire heart may improve the reproducibility of the H/CL ratio measurement.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Radiology, Hokkaido Cardiovascular Hospital, Hokkaido, Japan.
- Department of Radiology, Jichi Medical University Saitama Medical Center, Saitama, Japan.
- Department of Cardiovascular Biology and Medicine, Juntendo University Graduate School of Medicine, Tokyo, Japan.
- Department of Cardiology, Hokkaido Cardiovascular Hospital, Hokkaido, Japan.
Zitieren
APA
Saitou, T., Manabe, O., Nagase, A., Toyama, H., Kudo, T., Oyama-Manabe, N., & Aikawa, T. (2025). Impact of Region of Interest Size on Semi-Quantification of Myocardial 99mTc-pyrophosphate Uptake in Suspected Transthyretin Cardiac Amyloidosis. Annals of Nuclear Cardiology, 11(1), 33-38. https://doi.org/10.17996/anc.25-00005
Vancouver
Saitou T, Manabe O, Nagase A, Toyama H, Kudo T, Oyama-Manabe N, et al. Impact of Region of Interest Size on Semi-Quantification of Myocardial 99mTc-pyrophosphate Uptake in Suspected Transthyretin Cardiac Amyloidosis. Annals of Nuclear Cardiology. 2025;11(1):33-38. doi:10.17996/anc.25-00005
BibTeX
@article{Saitou2025,
author = {Saitou, Toshinori and Manabe, Osamu and Nagase, Atsushi and Toyama, Hiroaki and Kudo, Tamaki and Oyama-Manabe, Noriko and Aikawa, Tadao},
title = {Impact of Region of Interest Size on Semi-Quantification of Myocardial 99mTc-pyrophosphate Uptake in Suspected Transthyretin Cardiac Amyloidosis},
journal = {Annals of Nuclear Cardiology},
year = {2025},
volume = {11},
number = {1},
pages = {33--38},
doi = {10.17996/anc.25-00005}
}
EUVIMED