Overvoltage by Ferroresonance on a Rural Distribution Feeder: Case Report and Simulation
Inge CUC · 2015
DOI: 10.17981/ingecuc.11.1.2015.03 ↗Kurz gefasst
Fallbericht in der Zeitschrift Inge CUC, 2015. Verfasst von Guillermo F. Di Mauro und 3 weiteren Autor:innen. Die Arbeit wurde bisher 4-mal zitiert (Crossref).
Abstract (Originalsprache)
The objective of this work was to analyze an overvoltage case in a rural distribution feeder belonging to an electrical distribution company in the southeast of the Buenos Aires Province in Argentina. The network was modeled in the Electromagnetic Transients Program, based on the electrical parameters that make up the circuit, in order to evaluate its behavior under various switching and load states. The simulation analysis showed that during certain operation and load situations, the conditions for the overvoltage phenomenon occurred, causing a voltage increase in the single-phase transformer feeding. The guidelines for prevention and control of the phenomenon were provided taking into account the results obtained in the study. Key words— Overvoltage, ferroresonance, rural electrical distribution, fuse opening, ATPDraw, nonlinear circuits. Resumen-El objetivo del trabajo presentado fue el de analizar un caso de sobretensión en un sistema de distribución de energía eléctrica rural (13,2kV) perteneciente a una Cooperativa de Electricidad del sudeste de la Policía de Buenos Aires, Rep. Argentina. A partir de los parámetros que componen el circuito eléctrico se modeló la red dentro del entorno del programa computacional Electromagnetic Transients Program, con el fin de evaluar su comportamiento ante distintas maniobras de interrupción y estados de carga. El análisis de la simulación demostró que, en ciertas situaciones de operación y carga, se conjugaron las condiciones para la ocurrencia del fenómeno de ferrorresonancia, ocasionando la elevación de tensión de alimentación en transformadores monofásicos. Considerando los resultados del estudio, se brindaron pautas a tener en cuenta para la prevención y control del fenómeno. Palabras claves-Sobretensiones. Ferroresonancia. Distribución eléctrica rural. Apertura de fusibles. ATPDraw. Circuitos no lineales. * Article derived from the research project “Quality of Electricity”. Funded by Universidad de Mar del Plata. Start date: January 1, 2015. Completion Date: December 31, 2016. INGE CUC, Vol. 11, N° 1, pp 34-47, Junio, 2015 © The author; licensee Universidad de la Costa CUC. INGE CUC 11(1), pp. 34-47. January June, 2015 Barranquilla. ISSN 0122-6517 Printed, ISSN 2382-4700 Online DOI: http://dx.doi.org/10.17981/ingecuc.11.1.2015.03 35 Inge CuC, Vol. 11, n° 1, pp 34-47, Junio, 2015
Zitieren
APA
Mauro, G. F. D., Ferreyra, R., Suárez, J. A., & Jurado, A. D. (2015). Overvoltage by Ferroresonance on a Rural Distribution Feeder: Case Report and Simulation. Inge CUC. https://doi.org/10.17981/ingecuc.11.1.2015.03
Vancouver
Mauro GFD, Ferreyra R, Suárez JA, Jurado AD. Overvoltage by Ferroresonance on a Rural Distribution Feeder: Case Report and Simulation. Inge CUC. 2015. doi:10.17981/ingecuc.11.1.2015.03
BibTeX
@article{Mauro2015,
author = {Mauro, Guillermo F. Di and Ferreyra, Rubén and Suárez, Juan A. and Jurado, Alejandro D.},
title = {Overvoltage by Ferroresonance on a Rural Distribution Feeder: Case Report and Simulation},
journal = {Inge CUC},
year = {2015},
doi = {10.17981/ingecuc.11.1.2015.03}
}
EUVIMED