EUVIMEDEUVIMED entdecken
Crossref

Analysis of Heat Transfer Using the Computational Fluid Dynamics Method in the Design of a Condenser for a Pyrolysis System

Rizal Firmansyah, Raka M Sulistiyo, Rany P Dewi, Arif R Saleh, Cong-Bihn Dihn

Journal of Mechanical Engineering Science and Technology (JMEST) · 21.11.2026 · 10 (2) · 412-427

DOI: 10.17977/2580-2402.1262 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Mechanical Engineering Science and Technology (JMEST), online erschienen am 21.11.2026. Verfasst von Rizal Firmansyah und 4 weiteren Autor:innen.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The amount of bio-oil produced in a pyrolysis system is influenced by various factors, such as biomass characteristics, pyrolysis operating conditions, and the effectiveness of the condensation system. Therefore, designing a condenser capable of enhancing heat transfer efficiency is one of the factors in optimizing the condensation process and increasing bio-oil. This study aims to analyze the effect of variations in the number of tubes and baffles on the heat transfer characteristics of a shell-and-tube condenser using the Computational Fluid Dynamics (CFD) method. The condenser was designed using 304 stainless steel with a constant heat transfer area of 0.1508 m². Numerical simulations were performed using CFD software, with the hot fluid being steam from biomass pyrolysis at a temperature of 500°C and the cooling fluid being water at a temperature of 25°C. The variations analyzed included configurations with 8 tubes of 20 mm diameter with 4 and 8 baffles, as well as 16 tubes of 10 mm diameter with 4 and 8 baffles. The simulation results showed that the condenser’s geometric configuration significantly affects heat transfer performance. The 16-tube, 10-mm-diameter condenser design with 4 baffles produced the highest heat transfer rate of 64,240 W and the largest bio-oil volume of 0.533 L. Meanwhile, the 16-tube, 10-mm-diameter configuration with 8 baffles resulted in the lowest outlet temperature of 73.61°C but caused an increase in pressure drop. The number of tubes and baffles can improve the thermal performance of the condenser, thereby potentially enhancing the condensation process of pyrolysis vapor into bio-oil.

Zitieren

APA

Firmansyah, R., Sulistiyo, R. M., Dewi, R. P., Saleh, A. R., & Dihn, C. (2026). Analysis of Heat Transfer Using the Computational Fluid Dynamics Method in the Design of a Condenser for a Pyrolysis System. Journal of Mechanical Engineering Science and Technology (JMEST), 10(2), 412-427. https://doi.org/10.17977/2580-2402.1262

Vancouver

Firmansyah R, Sulistiyo RM, Dewi RP, Saleh AR, Dihn C. Analysis of Heat Transfer Using the Computational Fluid Dynamics Method in the Design of a Condenser for a Pyrolysis System. Journal of Mechanical Engineering Science and Technology (JMEST). 2026;10(2):412-427. doi:10.17977/2580-2402.1262

BibTeX
@article{Firmansyah2026,
  author = {Firmansyah, Rizal and Sulistiyo, Raka M and Dewi, Rany P and Saleh, Arif R and Dihn, Cong-Bihn},
  title = {Analysis of Heat Transfer Using the Computational Fluid Dynamics Method in the Design of a Condenser for a Pyrolysis System},
  journal = {Journal of Mechanical Engineering Science and Technology (JMEST)},
  year = {2026},
  volume = {10},
  number = {2},
  pages = {412--427},
  doi = {10.17977/2580-2402.1262}
}
Kostenlos starten →