EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

The role of elastic intramedullary reinforcement in lower limb lengthening

Denis V. Tropin, Akhmed D. Tomov, Nikita S. Gvozdev, Dmitriy A. Popkov

N.N. Priorov Journal of Traumatology and Orthopedics · 03.02.2026 · 33 (2) · 279-290

DOI: 10.17816/vto657504 ↗

Kurz gefasst

Fachartikel in der Zeitschrift N.N. Priorov Journal of Traumatology and Orthopedics, online erschienen am 03.02.2026. Verfasst von Denis V. Tropin und 3 weiteren Autor:innen. Die Arbeit nennt 42 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: Lower limb lengthening using external fixation devices combined with elastic intramedullary reinforcement offers several advantages over the classical approach. This technique excludes injury to the growth plates in children; the elasticity of intramedullary rods does not contradict the principle of gradual distraction, thereby ensuring high precision of limb reconstruction; and after removal of the external fixation device, elastic rods retained within the medullary canal enhance the mechanical strength of the lengthened bone. AIM: The work aimed to evaluate the effectiveness of lower limb lengthening outcomes in patients with congenital limb shortening treated using combined techniques, depending on the type of elastic intramedullary rods used: titanium rods with composite calcium phosphate coating versus uncoated rods. METHODS: The study included 65 patients with a mean age of 12.6 years (5–22 years). Femoral lengthening was performed in 19 patients, monofocal tibial lengthening in 30 patients, and bifocal tibial lengthening in 16 patients. Treatment was carried out at the Ilizarov National Medical Research Center for Traumatology and Orthopedics between 2017 and 2020. Only patients with congenital limb shortening were included in the analysis. Treatment outcomes were assessed 12 months after removal of the external fixation device. RESULTS: Three patient groups were formed according to the type of lengthening performed: monofocal femoral lengthening, monofocal tibial lengthening, and bifocal tibial lengthening. Two-way analysis of variance revealed a significant combined effect of rod type (p = 0.036) and patient age (p = 0.038) on the external fixation index in bifocal tibial lengthening. For the first time, the absence of a significant effect of hydroxyapatite coating on the external fixation index was demonstrated between the compared groups during limb lengthening performed using titanium intramedullary rods either with or without hydroxyapatite coating. Three cases of deformity or fracture at the lengthening site required unplanned surgical intervention, as well as one case of fracture of the regenerate bone at the junction of intramedullary rods. CONCLUSION: In congenital lower limb shortening not associated with pathological bone formation, there was no difference in external fixation index between groups treated with titanium elastic intramedullary rods and those treated with hydroxyapatite-coated rods. The diameter of the intramedullary rods is a key factor in preventing fractures and deformities following limb lengthening.

Zitieren

APA

Tropin, D. V., Tomov, A. D., Gvozdev, N. S., & Popkov, D. A. (2026). The role of elastic intramedullary reinforcement in lower limb lengthening. N.N. Priorov Journal of Traumatology and Orthopedics, 33(2), 279-290. https://doi.org/10.17816/vto657504

Vancouver

Tropin DV, Tomov AD, Gvozdev NS, Popkov DA. The role of elastic intramedullary reinforcement in lower limb lengthening. N.N. Priorov Journal of Traumatology and Orthopedics. 2026;33(2):279-290. doi:10.17816/vto657504

BibTeX
@article{Tropin2026,
  author = {Tropin, Denis V. and Tomov, Akhmed D. and Gvozdev, Nikita S. and Popkov, Dmitriy A.},
  title = {The role of elastic intramedullary reinforcement in lower limb lengthening},
  journal = {N.N. Priorov Journal of Traumatology and Orthopedics},
  year = {2026},
  volume = {33},
  number = {2},
  pages = {279--290},
  doi = {10.17816/vto657504}
}
Kostenlos starten →