EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Effect of antibacterial surface modification of titanium screws on bacterial infection

Andrei S. Scriabin, Alexey V. Shakurov, Yuliya S. Lukina, Leonid L. Bionyshev-Abramov, Dmitriy V. Smolentsev, Natalia B. Serejnikova, Vladimir R. Vesnin, Elizaveta S. Skriabina, Petr A. Tsygankov

N.N. Priorov Journal of Traumatology and Orthopedics · 09.03.2026 · 33 (2) · 316-324

DOI: 10.17816/vto653399 ↗

Kurz gefasst

Fachartikel in der Zeitschrift N.N. Priorov Journal of Traumatology and Orthopedics, online erschienen am 09.03.2026. Verfasst von Andrei S. Scriabin und 8 weiteren Autor:innen. Die Arbeit nennt 21 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: Postoperative infections, including osteomyelitis, remain a cause of numerous complications in traumatology and orthopedics. Despite available preventive strategies, bacterial contamination following implantation of titanium devices into bone defects may result in prolonged treatment, disability, and even mortality. AIM: This study aimed to evaluate the effectiveness of an antibiotic immobilized on an anodized titanium implant surface in suppressing peri-implant bacterial infection. METHODS: A pilot single-center prospective study was conducted (study subjects: sexually mature male Wistar rats weighing 250–300 g and aged 4–6 months). The study was comparative and experimental, with the collection of both quantitative and qualitative data at a single time point. Six titanium screws without surface modification and six screws with surface modification were provided for testing by consecutive sampling. The implantation period was 14 days. The overall study duration was 2 months. A porous anodized coating loaded with gentamicin was prepared on the titanium screw surface. Screws were implanted into the tibia of Wistar rats with simultaneous inoculation of Staphylococcus aureus into the medullary canal. Histological and microcomputed-tomography (CT) analyses were performed to assess treatment efficacy. RESULTS: In the control group, pronounced signs of bacterial bone infection were identified histologically and on CT images, characterized by greater bone rarefaction at the bone–implant interface. Reduced bone density was observed in the contact region between the implant and animal bone, with osteolytic zones predominantly on the implant side facing the proximal fragment. The defect margins were indistinct, and no tight bone–implant contact was detected. With the implemented surface modification of the implants, signs of bone rarefaction were less pronounced. Histological examination revealed newly formed bone tissue, in some cases closely apposed to the implanted screw. The area of newly formed bone was 39,311.4 ± 16,637.3 μm2 in the control group and 25,091.6 ± 16,834.7 μm2 in the experimental group, indicating no significant difference in osteogenesis (p = 0.216 0.05). No significant radiological signs of active inflammation or other pathological reactions at the bone–implant interface were observed in the experimental samples. CONCLUSION: The applied method of implant surface preparation with subsequent gentamicin loading demonstrated effectiveness in suppressing bacterial infection and reducing osteolysis in an in vivo model. The use of antibacterial agents did not exert a significant negative effect on osseointegration and was associated with more rapid maturation of newly formed bone tissue. The study results are useful for assessing future directions and identifying potential approaches to manage postoperative infectious complications.

Zitieren

APA

Scriabin, A. S., Shakurov, A. V., Lukina, Y. S., Bionyshev-Abramov, L. L., Smolentsev, D. V., Serejnikova, N. B., Vesnin, V. R., Skriabina, E. S., & Tsygankov, P. A. (2026). Effect of antibacterial surface modification of titanium screws on bacterial infection. N.N. Priorov Journal of Traumatology and Orthopedics, 33(2), 316-324. https://doi.org/10.17816/vto653399

Vancouver

Scriabin AS, Shakurov AV, Lukina YS, Bionyshev-Abramov LL, Smolentsev DV, Serejnikova NB, et al. Effect of antibacterial surface modification of titanium screws on bacterial infection. N.N. Priorov Journal of Traumatology and Orthopedics. 2026;33(2):316-324. doi:10.17816/vto653399

BibTeX
@article{Scriabin2026,
  author = {Scriabin, Andrei S. and Shakurov, Alexey V. and Lukina, Yuliya S. and Bionyshev-Abramov, Leonid L. and Smolentsev, Dmitriy V. and Serejnikova, Natalia B. and Vesnin, Vladimir R. and Skriabina, Elizaveta S. and Tsygankov, Petr A.},
  title = {Effect of antibacterial surface modification of titanium screws on bacterial infection},
  journal = {N.N. Priorov Journal of Traumatology and Orthopedics},
  year = {2026},
  volume = {33},
  number = {2},
  pages = {316--324},
  doi = {10.17816/vto653399}
}
Kostenlos starten →