EUVIMEDEUVIMED entdecken
Fall-Kontroll-StudieOpen Access · CC BY-NC-ND 4.0

Finite element analysis of the effects of orthodontic force on a microimplant and maxillary structures: A case-control study

Roman A. Fadeev, Irina K. Shevchenko

Acta Universitatis Dentistriae et Chirurgiae Maxillofacialis · 30.12.2025 · 3 (4) · 150-155

DOI: 10.17816/uds697917 ↗

Kurz gefasst

Fall-Kontroll-Studie in der Zeitschrift Acta Universitatis Dentistriae et Chirurgiae Maxillofacialis, online erschienen am 30.12.2025. Verfasst von Roman A. Fadeev und 1 weiteren Autor:innen. Die Arbeit nennt 8 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: Orthodontic microimplants placed in the infrazygomatic region are increasingly used in clinical practice. However, no systematic studies have been identified that comprehensively characterize the anatomy of this region and the magnitude of forces acting on a microimplant placed in the infrazygomatic region. AIM: To evaluate the effects of orthodontic force applied to a microimplant and the surrounding maxillary structures using finite element analysis. METHODS: A digital model of the maxilla was constructed for a patient undergoing orthodontic treatment with a fixed appliance system and a microimplant placed in the infrazygomatic region. Finite element analysis was performed to assess the influence of orthodontic force on the microimplant and adjacent maxillary structures (including the movable oral mucosa, the cortical plate, and the cancellous bone of the alveolar process). RESULTS: Under applied loading, the model demonstrated changes in physical parameters. The total deformation of the microimplant was 0.0002 mm, which may be interpreted as minimal and not affecting its stability. Equivalent stress in the model was concentrated in the cortical plate of the maxilla, with the limit reaching 0.021 MPa. Due to the high density of the cortical bone, equivalent stress values in the cancellous bone were several times lower. CONCLUSION: The deformation processes were localized and remained within physiological limits, confirming appropriate load distribution between the implant and surrounding tissues.

Zitieren

APA

Fadeev, R. A., & Shevchenko, I. K. (2025). Finite element analysis of the effects of orthodontic force on a microimplant and maxillary structures: A case-control study. Acta Universitatis Dentistriae et Chirurgiae Maxillofacialis, 3(4), 150-155. https://doi.org/10.17816/uds697917

Vancouver

Fadeev RA, Shevchenko IK. Finite element analysis of the effects of orthodontic force on a microimplant and maxillary structures: A case-control study. Acta Universitatis Dentistriae et Chirurgiae Maxillofacialis. 2025;3(4):150-155. doi:10.17816/uds697917

BibTeX
@article{Fadeev2025,
  author = {Fadeev, Roman A. and Shevchenko, Irina K.},
  title = {Finite element analysis of the effects of orthodontic force on a microimplant and maxillary structures: A case-control study},
  journal = {Acta Universitatis Dentistriae et Chirurgiae Maxillofacialis},
  year = {2025},
  volume = {3},
  number = {4},
  pages = {150--155},
  doi = {10.17816/uds697917}
}
Kostenlos starten →