EUVIMEDEUVIMED entdecken
Crossref

A Compact Battery as a Cause of Fatal Bleeding: A Clinical Case with a Literature Review.

Irina M. Kotovan, Dmitry Sergeevich Labuzov

Russian Journal of Pediatric Surgery · 18.11.2026

DOI: 10.17816/ps944 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Russian Journal of Pediatric Surgery, online erschienen am 18.11.2026. Verfasst von Irina M. Kotovan und 1 weiteren Autor:innen. Die Arbeit nennt 19 Literaturangaben.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The rapid emergence of technology, devices, and toys powered by button batteries has increased the problem of esophageal foreign bodies, especially in young children. This is due to the anatomical and physiological structural features and the proportionality of the lumens of physiological stenosis in the esophagus and the diameter of the battery. When entering biological environments, such a foreign body behaves aggressively, leading to the development of combined effects (compression, obstruction, and electrochemical burns). This article presents a clinical case of a patient admitted to the department with gastrointestinal bleeding. It developed more than a month after removing a battery. It was removed 4.5 hours after ingestion. This procedure was challenging due to ischemia, edema, and necrosis of the surrounding tissues caused by the battery's ingestion. The resulting hydroxyl anions led to the development of a liquefaction burn, which spread to deeper layers of the organ even after the foreign body was removed. The pathological processes in the child's body continued for more than a month and led to the formation of a perforation, then penetration into the aorta, followed by aortic bleeding and death. The depth of the pathological processes was not visible even during endoscopic and radiographic examinations. During the initial examination, the defect was approximately 2.0-2.5 cm in diameter and approximately 1-2 mm deep. Follow-up examinations revealed positive dynamics, including a decrease in the defect's size. A three-week follow-up examination revealed ulcer epithelialization, with its size decreasing to 1.0 x 0.3 cm. It should be noted that the child was receiving conservative treatment and enteral nutrition, which in turn contributed to glandular hypersecretion and irritant effects on the damaged esophageal mucosa. Despite this, the child's condition remained satisfactory until the last minutes of his life. Based on the above, it is essential to carefully assess the condition of the mucosa at the site of the foreign body during its removal and to choose the appropriate management strategy after foreign body removal, taking into account the aggressive nature of the foreign body.

Zitieren

APA

Kotovan, I. M., & Labuzov, D. S. (2026). A Compact Battery as a Cause of Fatal Bleeding: A Clinical Case with a Literature Review. Russian Journal of Pediatric Surgery. https://doi.org/10.17816/ps944

Vancouver

Kotovan IM, Labuzov DS. A Compact Battery as a Cause of Fatal Bleeding: A Clinical Case with a Literature Review. Russian Journal of Pediatric Surgery. 2026. doi:10.17816/ps944

BibTeX
@article{Kotovan2026,
  author = {Kotovan, Irina M. and Labuzov, Dmitry Sergeevich},
  title = {A Compact Battery as a Cause of Fatal Bleeding: A Clinical Case with a Literature Review},
  journal = {Russian Journal of Pediatric Surgery},
  year = {2026},
  doi = {10.17816/ps944}
}
Kostenlos starten →