EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Effectiveness and safety of Nd:YAG laser versus E-Light technology in percutaneous coagulation of facial telangiectasias

Evgeniia A. Egorova, Roman E. Kalinin, Igor A. Suchkov

I.P. Pavlov Russian Medical Biological Herald · 31.03.2026 · 34 (1) · 63-70

DOI: 10.17816/pavlovj677809 ↗

Kurz gefasst

Fachartikel in der Zeitschrift I.P. Pavlov Russian Medical Biological Herald, online erschienen am 31.03.2026. Verfasst von Evgeniia A. Egorova und 2 weiteren Autor:innen. Die Arbeit nennt 15 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: One most modern method to correct telangiectasias is percutaneous coagulation. A large number of available devices, lack of optimized protocols and predictable results of procedures, make studying the effectiveness and safety of methods for correcting facial vascular pathologies a pressing issue today. AIM: To conduct a comparative analysis of the effectiveness and safety of removing facial telangiectasias using a neodymium laser with 1064 nm wavelength and 650 μs pulse width, and using a device based on E-Light technology (E-Light device), which represents the synergy of intense pulsed light (IPL) and radiofrequency (RF). METHODS: A prospective experimental randomized study was conducted. Each patient (n = 79) of two study groups underwent two sessions of laser obliteration of telangiectasias. The interval between procedures was 1 month. In group 1 (n = 39), obliteration was performed using a solid-state laser with neodymium-doped yttrium aluminum garnet as an active medium (Nd:YAG laser), in group 2 (n = 40), an E-Light device was used. The study groups were comparable in gender (р = 0.818), age (р = 0.147) and the initial number of telangiectasias (р = 0.062). The patients were conducted macrophotography and dermatoscopy of facial vascular lesions. After each obliteration session, pain sensations of patients were assessed on Visual Analogue Scale (VAS). RESULTS: The results of subjective pain assessment on VAS after each procedure showed a statistically significant differences between the groups: after the first and second obliteration sessions (р 0.0001), pain sensations were weaker in patients of group 1. Despite the absence of a statistically significant difference in the results in terms of the number of obliterated telangiectasias in the two groups (after the first obliteration session — р = 0.994, after the second obliteration session — р = 0.208), in group 1, 19.2% more telangiectasias have been cleared than in group 2. One patient (2.5%) of group 2 had hypopigmentation in the treated area 1 month after the second obliteration session. CONCLUSION: The effectiveness of obliteration of facial telangiectasias with Nd:YAG laser in terms of reducing vascular malformations was 19.2% greater than when using a E-Light device. The use of a Nd:YAG laser for two sessions of facial telangiectasia obliteration was safer than that of E-Light device.

Zitieren

APA

Egorova, E. A., Kalinin, R. E., & Suchkov, I. A. (2026). Effectiveness and safety of Nd:YAG laser versus E-Light technology in percutaneous coagulation of facial telangiectasias. I.P. Pavlov Russian Medical Biological Herald, 34(1), 63-70. https://doi.org/10.17816/pavlovj677809

Vancouver

Egorova EA, Kalinin RE, Suchkov IA. Effectiveness and safety of Nd:YAG laser versus E-Light technology in percutaneous coagulation of facial telangiectasias. I.P. Pavlov Russian Medical Biological Herald. 2026;34(1):63-70. doi:10.17816/pavlovj677809

BibTeX
@article{Egorova2026,
  author = {Egorova, Evgeniia A. and Kalinin, Roman E. and Suchkov, Igor A.},
  title = {Effectiveness and safety of Nd:YAG laser versus E-Light technology in percutaneous coagulation of facial telangiectasias},
  journal = {I.P. Pavlov Russian Medical Biological Herald},
  year = {2026},
  volume = {34},
  number = {1},
  pages = {63--70},
  doi = {10.17816/pavlovj677809}
}
Kostenlos starten →