EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Comparison of deformation models of the tympanic membrane

Sergey A. Muslov, Pavel Yu. Sukhochev, Mikhail V. Chistiakov, Nataliia V. Zaitseva, Aleksandr A. Korneev, Dmitriy I. Polyakov

Medical academic journal · 30.03.2026 · 26 (1) · 81-90

DOI: 10.17816/maj635663 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Medical academic journal, online erschienen am 30.03.2026. Verfasst von Sergey A. Muslov und 5 weiteren Autor:innen. Die Arbeit nennt 24 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: The development of methods for assessing the conformity of the physical properties of artificial materials with the physiological parameters of native tissues and organs is one of the pressing tasks of tissue engineering. This also applies to artificial wound dressings used in tympanoplasty operations. AIM: To determine a group of deformation models of the human eardrum for the purpose of screening artificial materials for surgical replacement of its defects. METHODS: Formally defined deformation models were considered: elastic linear, bilinear, trilinear, exponential, and hyperelastic models. Among the hyperelastic models, the neo-Hookean, 2-parameter Mooney–Rivlin, 1st-order Ogden, 3rd-order Yeoh, 2nd-order polynomial, and Veronda–Westmann model were analyzed. The agreement between the calculated deformation data and experimental data was assessed using descriptive statistics. The Mathcad 15.0 and ANSYS 2022 R2 software packages were used for the calculations. RESULTS: The numerical values of the parameters of the linear, bilinear, trilinear, exponential, and hyperelastic family models were determined. Of the studied hyperelastic models, the polynomial model demonstrated the lowest mean square approximation error (SD = 0.002 MPa); the highest correlation between experimental and model data was demonstrated by the polynomial, Ogden, and Yeoh models (r = 0.9999). CONCLUSION: The polynomial model is the most preferable for describing the mechanical properties of such a biological object as the eardrum, which experiences various deformation modes, and can be used for screening artificial materials for replacing defects in tympanic membrane grafting. Among other models, the smallest discrepancy between model and experimental data was found for the exponential model (SD = 0.002 MPa, r = 0.9998). The obtained data may be useful in the field of regenerative medicine and tissue engineering in the search for replacement materials for reconstructive interventions on the middle ear.

Zitieren

APA

Muslov, S. A., Sukhochev, P. Y., Chistiakov, M. V., Zaitseva, N. V., Korneev, A. A., & Polyakov, D. I. (2026). Comparison of deformation models of the tympanic membrane. Medical academic journal, 26(1), 81-90. https://doi.org/10.17816/maj635663

Vancouver

Muslov SA, Sukhochev PY, Chistiakov MV, Zaitseva NV, Korneev AA, Polyakov DI. Comparison of deformation models of the tympanic membrane. Medical academic journal. 2026;26(1):81-90. doi:10.17816/maj635663

BibTeX
@article{Muslov2026,
  author = {Muslov, Sergey A. and Sukhochev, Pavel Yu. and Chistiakov, Mikhail V. and Zaitseva, Nataliia V. and Korneev, Aleksandr A. and Polyakov, Dmitriy I.},
  title = {Comparison of deformation models of the tympanic membrane},
  journal = {Medical academic journal},
  year = {2026},
  volume = {26},
  number = {1},
  pages = {81--90},
  doi = {10.17816/maj635663}
}
Kostenlos starten →