Diagnostic accuracy of high-resolution mass spectrometry (hr-ms) in analysis of novel psychoactive substances in biological samples in forensic toxicology practice
Russian Journal of Forensic Medicine · 08.07.2026
DOI: 10.17816/fm16353 ↗Kurz gefasst
Fachartikel in der Zeitschrift Russian Journal of Forensic Medicine, online erschienen am 08.07.2026. Verfasst von Azaliya A. Lutfullina und 11 weiteren Autor:innen.
Abstract (Originalsprache)
The rapid increase in the prevalence of novel psychoactive substances (NPS) and their continuous emergence pose new challenges for forensic toxicological analysis. Standard analytical methods, designed for the detection of known compounds, are not oriented towards identifying new analogues, thereby increasing the risk of diagnostic errors. In this context, high-resolution mass spectrometry (HRMS) is regarded as a platform capable of providing the necessary level of evidentiary value due to its combination of high specificity, sensitivity, and the capability for retrospective data analysis. The implementation of HRMS into routine practice in the Russian Federation is limited by the lack of systematic data on its diagnostic accuracy. This review analyzed 53 sources selected in accordance with the PRISMA-2020 guidelines. The search was conducted in the PubMed, ScienceDirect, eLibrary, and Google Scholar databases. It was demonstrated that QTOF and Orbitrap analyzers enable NPS identification with a mass error of less than 5 ppm, allowing for the differentiation of isomers and the determination of empirical formulas for unknown compounds. Various screening modes are described, including targeted analysis, suspect screening using databases (HighResNPS), and non-targeted analysis. The effectiveness of the retrospective approach, which allows for the detection of NPS in previously acquired data without re-analyzing samples, was shown. Data on the method's sensitivity were systematized; limits of detection in blood and urine reach sub-ng/mL concentrations, which is sufficient for identifying NPS in both acute poisoning cases and at trace levels. The impact of matrix effects on analytical accuracy and strategies for their minimization, including the use of isotopically labeled standards, were examined. The specific aspects of working with various biological specimens (blood, urine, hair), considering NPS metabolism, as well as autopsy material, were addressed separately. Practical recommendations for the implementation of HRMS into the practice of domestic laboratories were formulated.
Zitieren
APA
Lutfullina, A. A., Ivanova, M. E., Aleksandrova, M. R., Chubanova, S. E., Saveleva, A. A., Povarova, A. O., Mallaeva, A. D., Tuvardzhiev, A. A., Shalunts, D. V., Milyukova, S. A., Lesnaya, E. A., & Khasaeva, A. R. (2026). Diagnostic accuracy of high-resolution mass spectrometry (hr-ms) in analysis of novel psychoactive substances in biological samples in forensic toxicology practice. Russian Journal of Forensic Medicine. https://doi.org/10.17816/fm16353
Vancouver
Lutfullina AA, Ivanova ME, Aleksandrova MR, Chubanova SE, Saveleva AA, Povarova AO, et al. Diagnostic accuracy of high-resolution mass spectrometry (hr-ms) in analysis of novel psychoactive substances in biological samples in forensic toxicology practice. Russian Journal of Forensic Medicine. 2026. doi:10.17816/fm16353
BibTeX
@article{Lutfullina2026,
author = {Lutfullina, Azaliya A. and Ivanova, Marina E. and Aleksandrova, Maria R. and Chubanova, Sofiya E. and Saveleva, Anastasia A. and Povarova, Alisa O. and Mallaeva, Amina D. and Tuvardzhiev, Avdey A. and Shalunts, Diana= V. and Milyukova, Sofya A. and Lesnaya, Eleonora A. and Khasaeva, Amina R.},
title = {Diagnostic accuracy of high-resolution mass spectrometry (hr-ms) in analysis of novel psychoactive substances in biological samples in forensic toxicology practice},
journal = {Russian Journal of Forensic Medicine},
year = {2026},
doi = {10.17816/fm16353}
}
EUVIMED