EUVIMEDEUVIMED entdecken
QuerschnittstudieOpen Access · CC BY-NC-ND 4.0

Selection of the optimal configuration of electroencephalographic electrodes for identifying cognitive load in healthy adults: a cross-sectional study

Alexander E. Dedkov, Denis A. Andrikov

Digital Diagnostics · 05.06.2026 · 7 (2) · 187-200

DOI: 10.17816/dd653468 ↗

Kurz gefasst

Querschnittstudie in der Zeitschrift Digital Diagnostics, online erschienen am 05.06.2026. Verfasst von Alexander E. Dedkov und 1 weiteren Autor:innen. Die Arbeit nennt 12 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: Cognitive load monitoring plays a key role in personalized neurorehabilitation and evaluation of educational program effectiveness. However, existing electroencephalographic systems with a large number of electrodes are technically complex and unsuitable for everyday use. Insufficient studies have explored the minimum electrode configurations necessary for a reliable assessment of the tasks' complexity under cognitive load. AIM: To determine the minimum electroencephalographic electrode configurations that ensure reliable identification of cognitive load levels during multitasking (MATB-II) and working memory (N-Back) tasks, using feature importance and attribution methods, as well as to evaluate the applicability of electrode configurations proposed in previous studies. METHODS: A cross-sectional, single-center study using retrospective data was conducted. Cognitive load was assessed using MATB-II and N-Back tasks from the open COGnitive Brain-Computer Interface dataset. Raw electroencephalographic signals were filtered and subjected to spectral analysis with allocation of power in the θ, α, β and γ bands. The Kolmogorov–Arnold Networks model was used for training and selecting informative features to enable feature importance attribution and determine the minimum electrode configurations. RESULTS: The sns_att4 configuration with four channels and a value of F1 = 0.738 turned out to be the best for the MATB-II task. The sns_gp8 configuration with eight channels and F1 = 0.695 is the best for the N-Back task. Using the Kolmogorov–Arnold Networks model combined with the attribution method enabled the identification of compact electrode configurations (3–10 channels) that maintain high classification accuracy. The optimal 9-electrode configuration (ours_9) for MATB-II provided the mean F1 of 0.714. The three-electrode configuration (ours_3) for N-Back reached F1 = 0.617. Statistical analysis has confirmed that the proposed configurations are competitive with previously published schemes and, in some cases (ours_3 for N-Back), demonstrate an advantage with a minimum number of channels. CONCLUSION: The identified configurations with a limited number of electrodes ensure reliability in determining a cognitive load. They can be used at home setting at the third stage of rehabilitation and integrated into portable neural devices.

Zitieren

APA

Dedkov, A. E., & Andrikov, D. A. (2026). Selection of the optimal configuration of electroencephalographic electrodes for identifying cognitive load in healthy adults: a cross-sectional study. Digital Diagnostics, 7(2), 187-200. https://doi.org/10.17816/dd653468

Vancouver

Dedkov AE, Andrikov DA. Selection of the optimal configuration of electroencephalographic electrodes for identifying cognitive load in healthy adults: a cross-sectional study. Digital Diagnostics. 2026;7(2):187-200. doi:10.17816/dd653468

BibTeX
@article{Dedkov2026,
  author = {Dedkov, Alexander E. and Andrikov, Denis A.},
  title = {Selection of the optimal configuration of electroencephalographic electrodes for identifying cognitive load in healthy adults: a cross-sectional study},
  journal = {Digital Diagnostics},
  year = {2026},
  volume = {7},
  number = {2},
  pages = {187--200},
  doi = {10.17816/dd653468}
}
Kostenlos starten →