Restoration of sensory feedback after lower limb amputation using stimulation of the dorsal root ganglia and spinal cord: a case report
Journal of Clinical Practice · 15.11.2026 · 17 (3) · 206-218
DOI: 10.17816/clinpract718223 ↗Kurz gefasst
Fallbericht in der Zeitschrift Journal of Clinical Practice, online erschienen am 15.11.2026. Verfasst von Anna A. Dudorova und 7 weiteren Autor:innen. Die Arbeit nennt 25 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).
Abstract (Originalsprache)
BACKGROUND: Lower limb amputations are approximately three times more common than upper limb amputations, yet sensory feedback restoration methods, including sensory mapping, have historically been developed mainly for the upper limb. In patients with lower limb amputation, the lack of information about the interaction between the prosthesis and the ground increases cognitive load and the risk of falls. Dorsal root ganglion stimulation (DRG-S) and spinal cord stimulation (SCS) are considered as means of delivering an artificial sensory signal; however, comparative data on the perceptual patterns and motor side effects they evoke, and on their use in closed-loop biofeedback in such patients, are lacking. CLINICAL CASE DESCRIPTION: We report a 69 years old male patient with a right lower leg amputation at the level of the distal third following a mine-blast injury sustained 4 years before the observation, and phantom limb pain (background pain of 3–6 points on the visual analogue scale with paroxysms of 8–10 points occurring 15–20 times a day). The patient underwent implantation of test DRG (L5–S1) and SCS (L4–L5) electrodes. During sensory mapping with concurrent surface electromyography, S1 DRG stimulation evoked focal sensations in the phantom phalanges without motor responses across the entire amplitude range (up to 8 mA), whereas SCS projected to the heel area and was accompanied by pronounced muscle contractions and contralateral radiation. In closed-loop testing with a sensory insole, stimulus recognition accuracy with the DRG electrode and the prosthesis worn was 87% with both electrical and sham stimulation. With the SCS electrode and the prosthesis removed, accuracy increased from 80% to 97% (sensitivity 100%) after a 30-minute sensorimotor adaptation period. The protocol was completed in full, and no serious adverse events were recorded. CONCLUSION: This case represents the pilot phase of an ongoing clinical study on the development of sensory prostheses and the restoration of somatosensory sensitivity. The patient’s protocol was completed in full, with no serious adverse events recorded. The findings suggest that sensory mapping techniques and biofeedback can be adapted for patients with lower limb amputation. DRG stimulation produced focal sensations without motor artifacts, SCS required a period of sensorimotor adaptation, and when evaluating feedback systems, it was necessary to control for the mechanical transmission of pressure through the prosthesis socket.
Zitieren
APA
Dudorova, A. A., Neklyudova, A. K., Grigoreva, O. A., Benachour, A., Churnosov, M. A., Sintsov, M. Y., Biktimirov, A. R., & Soghoyan, G. A. (2026). Restoration of sensory feedback after lower limb amputation using stimulation of the dorsal root ganglia and spinal cord: a case report. Journal of Clinical Practice, 17(3), 206-218. https://doi.org/10.17816/clinpract718223
Vancouver
Dudorova AA, Neklyudova AK, Grigoreva OA, Benachour A, Churnosov MA, Sintsov MY, et al. Restoration of sensory feedback after lower limb amputation using stimulation of the dorsal root ganglia and spinal cord: a case report. Journal of Clinical Practice. 2026;17(3):206-218. doi:10.17816/clinpract718223
BibTeX
@article{Dudorova2026,
author = {Dudorova, Anna A. and Neklyudova, Anastasia K. and Grigoreva, Olga A. and Benachour, Asma and Churnosov, Maksim A. and Sintsov, Mikhail Y. and Biktimirov, Artur R. and Soghoyan, Gurgen A.},
title = {Restoration of sensory feedback after lower limb amputation using stimulation of the dorsal root ganglia and spinal cord: a case report},
journal = {Journal of Clinical Practice},
year = {2026},
volume = {17},
number = {3},
pages = {206--218},
doi = {10.17816/clinpract718223}
}