The first experience with dynamic magnetic retraction in laparoscopic colon resections
Journal of Clinical Practice · 15.11.2026 · 17 (3) · 77-88
DOI: 10.17816/clinpract707772 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Clinical Practice, online erschienen am 15.11.2026. Verfasst von Alexey P. Kukhto und 7 weiteren Autor:innen. Die Arbeit nennt 5 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).
Abstract (Originalsprache)
BACKGROUND: Laparoscopic surgery of the colon requires reliable retraction of the organ, but existing methods (ligatures, clamps) carry a risk of perforation of the intestinal wall and do not allow dynamically changing the traction vector without additional punctures. The use of magnetic systems is limited by the binary mode of operation (on/off), which does not provide smooth control of gravity and multi-axial positioning in conditions of complex pelvic anatomy. The safety and effectiveness of dynamic magnetic retraction with electronic field strength control in colorectal resections, especially in oncological practice, remains unexplored. AIM: To evaluate the clinical safety and effectiveness of using a new dynamic magnetic retraction system with electronically controlled magnetic field strength and six-axis positioning to ensure adequate exposure of the surgical field in patients undergoing elective laparoscopic colon resections. METHODS: The prospective descriptive study included patients aged 46 to 78 years with histologically verified cancer of the cecum, ascending, descending or sigmoid colon who are subject to elective laparoscopic intervention in a single surgical hospital. The intervention under study was the intraoperative application of a magnetic system with dynamic control. The primary endpoint of safety was the frequency of intraoperative complications directly related to the use of a magnetic device. Additional outcomes included: the duration of surgery, the amount of blood loss, the need for additional ports, the number of lymph nodes removed, the frequency of R0 resection, as well as the frequency of postoperative complications (including seroma), the recovery time of peristalsis, and the duration of hospitalization. RESULTS: The study included 12 patients (7 men, 5 women; median age, 64 years). In all cases, the system provided adequate visualization of the surgical field without conversion or the use of additional trocar ports. There were no intraoperative complications associated with the magnetic device (0%; 95% CI 0–26.5). The median duration of the intervention was 170 minutes, and the median blood loss was 50 ml. The median number of lymph nodes removed was 12 (range, 8–18). R0 resection was achieved in all 12 patients. Peristaltic activity was restored on the second day, and the median discharge date was 10 days. There was one case of postoperative seroma (8.3%), and no deaths were reported. This study has limitations related to a small sample size and the lack of a control group, which currently prevents us from assessing the superiority of the method over standard approaches. CONCLUSION: The obtained data demonstrate that dynamic magnetic retraction with smooth adjustment of the force and traction vector is safe and provides adequate oncological results in laparoscopic colon resections.
Zitieren
APA
Kukhto, A. P., Baziyan-Kukhto, N. K., Bashankaev, B. N., Ishchenko, R. V., Dzhansyz, I. N., Filimonov, D. A., Kalachyov, M. V., & Bilikhodze, I. M. (2026). The first experience with dynamic magnetic retraction in laparoscopic colon resections. Journal of Clinical Practice, 17(3), 77-88. https://doi.org/10.17816/clinpract707772
Vancouver
Kukhto AP, Baziyan-Kukhto NK, Bashankaev BN, Ishchenko RV, Dzhansyz IN, Filimonov DA, et al. The first experience with dynamic magnetic retraction in laparoscopic colon resections. Journal of Clinical Practice. 2026;17(3):77-88. doi:10.17816/clinpract707772
BibTeX
@article{Kukhto2026,
author = {Kukhto, Alexey P. and Baziyan-Kukhto, Naira K. and Bashankaev, Badma N. and Ishchenko, Roman V. and Dzhansyz, Ivan N. and Filimonov, Dmitry A. and Kalachyov, Maxim V. and Bilikhodze, Ivan M.},
title = {The first experience with dynamic magnetic retraction in laparoscopic colon resections},
journal = {Journal of Clinical Practice},
year = {2026},
volume = {17},
number = {3},
pages = {77--88},
doi = {10.17816/clinpract707772}
}
EUVIMED