Background
To address instability after total hip arthroplasty (THA), a Reverse Hip Replacement System (RHRS) has been proposed, inspired by the concept of reverse total shoulder arthroplasty. The aim of the review — to gather reported results, explore early outcomes, and identify potential challenges of the reverse hip replacement system.
Methods
A systematic search in PubMed and Scopus databases was performed in March 2025 using predetermined search terms, which revealed an initial 656 results. Only four studies were eligible for inclusion: one biomechanical study and three clinical studies (one case series and two case reports).
Results
The three clinical studies included 24 patients aged 60 to 79 years; 13 (54.2%) were male, and all were diagnosed with advanced hip osteoarthritis. After follow-up ranging from 3 weeks to 24 months, all patients were satisfied with the results, except for 2 (8.3%). Detailed function and PROMs outcomes for 22 patients at 24 months of follow-up showed significant improvement in WOMAC, HHS, OHS, HOOS, SF-36 physical component summary (PCS), and ED-5D (p 0.05). However, there was a nonsignificant change in the SF-36 mental component summary (MCS) (p = 0.272). Radiological outcomes, as determined by RSA analysis, at 24 months for 18 acetabular cups showed a mean migration of 0.087±0.152 mm. The overall complication rate was 29.2% 7 (cases): one intraoperative calcar crack, one deep periprosthetic joint infection, one postoperative traumatic dislocation, one femoral neuropraxia, one occasional pain, and two recalcitrant iliotibial band syndrome. The biomechanical study results showed lower polyethylene wear debris equivalent to other systems, no wear debris due to metal-on-metal contact, and no signs of polyethylene edge or backside wear.
Conclusion
Besides the promising biomechanical results, early functional and radiological outcomes of the reverse hip replacement system are encouraging; however, the incidence of complications is considerably high. Moreover, the results should be interpreted cautiously owing to the small number of included patients and the short follow-up period.
Zitieren
APA
Khalifa, A. A. (2026). Reverse hip replacement system: addressing instability concerns or introducing new risks? A scoping review. Traumatology and Orthopedics of Russia, 32(2), 149-156. https://doi.org/10.17816/2311-2905-17859
Vancouver
Khalifa AA. Reverse hip replacement system: addressing instability concerns or introducing new risks? A scoping review. Traumatology and Orthopedics of Russia. 2026;32(2):149-156. doi:10.17816/2311-2905-17859
BibTeX
@article{Khalifa2026,
author = {Khalifa, Ahmed A.},
title = {Reverse hip replacement system: addressing instability concerns or introducing new risks? A scoping review},
journal = {Traumatology and Orthopedics of Russia},
year = {2026},
volume = {32},
number = {2},
pages = {149--156},
doi = {10.17816/2311-2905-17859}
}
EUVIMED