EUVIMEDEUVIMED entdecken
Crossref

Evaluation of Metallic Ion Release from Fixed Orthodontic Appliance in Two Different Mouthwashes and Distilled Water An In Vitro Study

Rawand Mahmood, Mahmoud Mohsin, Mansour Mohammad, Mohammed Shkur

Sulaimani Dental Journal · 2021

DOI: 10.17656/sdj-10131 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Sulaimani Dental Journal, 2021. Verfasst von Rawand Mahmood und 3 weiteren Autor:innen.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objectives

Biocompatibility is an essential requirement for orthodontic appliances, but it leaches metallic ions in the presence of saliva, prophylactic mouthwashes, and toothpaste. This study evaluates the amount of ion release from orthodontic brackets and archwires after immersing them in two different mouthwash and distilled water types.

Methods

Twenty-four orthodontic sets for one mandibular quadrant, including (five brackets), one buccal tube, and a half of the required length of CuNiTi archwires for each set were used. The samples were dipped in Ortho Kin, Kin Forte, distilled water, and measurements were taken at two time points, first after twenty-four hours and second after two weeks. Distilled water was used as the control group. Then the amount of metallic ion release is evaluated by ICP (Inductively Coupled Plasma) spectroscopy.

Results

Results showed that the highest concentration of metallic ion release was from samples containing Ortho Kin mouthwash (fluoridated) then the Kin Forte and distilled water.

Conclusions

Fluoridated mouthwash caused more metallic ion release from orthodontic appliances than non-fluoridated mouthwash and distilled water.

Zitieren

APA

Mahmood, R., Mohsin, M., Mohammad, M., & Shkur, M. (2021). Evaluation of Metallic Ion Release from Fixed Orthodontic Appliance in Two Different Mouthwashes and Distilled Water An In Vitro Study. Sulaimani Dental Journal. https://doi.org/10.17656/sdj-10131

Vancouver

Mahmood R, Mohsin M, Mohammad M, Shkur M. Evaluation of Metallic Ion Release from Fixed Orthodontic Appliance in Two Different Mouthwashes and Distilled Water An In Vitro Study. Sulaimani Dental Journal. 2021. doi:10.17656/sdj-10131

BibTeX
@article{Mahmood2021,
  author = {Mahmood, Rawand and Mohsin, Mahmoud and Mohammad, Mansour and Shkur, Mohammed},
  title = {Evaluation of Metallic Ion Release from Fixed Orthodontic Appliance in Two Different Mouthwashes and Distilled Water An In Vitro Study},
  journal = {Sulaimani Dental Journal},
  year = {2021},
  doi = {10.17656/sdj-10131}
}
Kostenlos starten →