DETERMINATION OF AIRFLOW RATE IN FLUIDIZED BED DRYING SYSTEM
JP Journal of Heat and Mass Transfer · 26.05.2026 · 39 (3) · 471-487
DOI: 10.17654/0973576326024 ↗Kurz gefasst
Fachartikel in der Zeitschrift JP Journal of Heat and Mass Transfer, online erschienen am 26.05.2026. Verfasst von Thi Viet Linh Nguyen und 4 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
The determination of airflow rate in a fluidized bed drying system is a critical requirement in fluidized bed drying operations, as it directly governs the fluidization regime and the efficiency of heat and mass transfer, particularly for high-quality agricultural products. This study developed and evaluated an experimental airflow measurement system using a cluster of three ISA 1932 standard nozzles integrated into a rectangular plenum chamber. The system’s performance was investigated across a fan operating frequency range of 20 Hz to 60 Hz. Airflow rates calculated from differential pressure $(\Delta p)$ at eight different static pressure tapping positions were cross-validated against reference values derived from duct centerline velocity measurements. Experimental results demonstrate a strong linear correlation between fan frequency and airflow velocity, consistent with centrifugal blower characteristics. The relative error between the two measurement methods fluctuated between 5.94 % and 24.31 %. Notably, the highest precision (error < 10 %) was consistently achieved at higher operating frequencies (55 – 60 Hz) and specifically at tapping positions 4 and 5, located toward the lower boundaries of the plenum chamber. This study identified an optimal pressure tapping configuration, demonstrating that while the multi-nozzle arrangement is a viable method for extending measurement ranges, accuracy is highly sensitive to the spatial location of the taps. To achieve optimal measurement accuracy, the static pressure taps were strategically positioned at the lower edges of the plenum chamber, where flow redistribution was most stable and less affected by localized turbulence. These findings provide a technical foundation for optimizing drying kinetics and enhancing energy efficiency in post-harvest processing.
Zitieren
APA
Nguyen, T. V. L., Nguyen, D. N., Pham, T. V., Nguyen, X. B., & Nguyen, N. Q. (2026). DETERMINATION OF AIRFLOW RATE IN FLUIDIZED BED DRYING SYSTEM. JP Journal of Heat and Mass Transfer, 39(3), 471-487. https://doi.org/10.17654/0973576326024
Vancouver
Nguyen TVL, Nguyen DN, Pham TV, Nguyen XB, Nguyen NQ. DETERMINATION OF AIRFLOW RATE IN FLUIDIZED BED DRYING SYSTEM. JP Journal of Heat and Mass Transfer. 2026;39(3):471-487. doi:10.17654/0973576326024
BibTeX
@article{Nguyen2026,
author = {Nguyen, Thi Viet Linh and Nguyen, Duc Nam and Pham, The Vu and Nguyen, Xuan Binh and Nguyen, Ngoc Quy},
title = {DETERMINATION OF AIRFLOW RATE IN FLUIDIZED BED DRYING SYSTEM},
journal = {JP Journal of Heat and Mass Transfer},
year = {2026},
volume = {39},
number = {3},
pages = {471--487},
doi = {10.17654/0973576326024}
}
EUVIMED