EUVIMEDEUVIMED entdecken
Crossref

Improved MRI methods to quantify retinal and choroidal blood flow detect decreased blood flow in a model of glaucoma

Diane Chernoff, Robert Honkanen, Andre Galenchik-Chan, Timothy Q. Duong, Zhao Hui JIANG, Eric R. Muir, David Tomorri

Carolina Digital Repository (University of North Carolina at Chapel Hill) · 05.06.2024

DOI: 10.17615/40pd-x688 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Carolina Digital Repository (University of North Carolina at Chapel Hill), erschienen am 05.06.2024. Verfasst von Diane Chernoff und 6 weiteren Autor:innen.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

Blood flow (BF) of the retinal and choroidal vasculatures can be quantitatively imaged using MRI. This study sought to improve methods of data acquisition and analysis for MRI of layer-specific retinal and choroidal BF and then applied this approach to detect reduced ocular BF in a well-established mouse model of glaucoma from both eyes.

Methods

Quantitative BF magnetic resonance imaging (MRI) was performed on glaucomatous DBA/2J and normal C57BL/6J mice. Arterial spin labeling MRI was applied to image retinal and choroidal BF using custom-made dual eye coils that could image both eyes during the same scan. Statistics using data from a single eye or two eyes were compared. BF values were calculated using two approaches. The BF rate per quantity of tissue was calculated as commonly done, and the peak BF values of the retinal and choroidal vasculatures were taken. Additionally, the BF rate per retinal surface area was calculated using a new analysis approach to attempt to reduce partial volume and variability by integrating BF over the retinal and choroidal depths.

Results

Ocular BF of both eyes could be imaged using the dual coil setup without effecting scan time. Intraocular pressure was significantly elevated in DBA/2J mice compared to C57BL/6J mice (P

Schlagwörter

retinal blood flowchoroidal blood flowglaucomaarterial spin labelingDBA/2J miceC57BL/6J miceocular blood flowintraocular pressurepartial volume effectglaucoma progression

Zitieren

APA

Chernoff, D., Honkanen, R., Galenchik-Chan, A., Duong, T. Q., JIANG, Z. H., Muir, E. R., & Tomorri, D. (2024). Improved MRI methods to quantify retinal and choroidal blood flow detect decreased blood flow in a model of glaucoma. Carolina Digital Repository (University of North Carolina at Chapel Hill). https://doi.org/10.17615/40pd-x688

Vancouver

Chernoff D, Honkanen R, Galenchik-Chan A, Duong TQ, JIANG ZH, Muir ER, et al. Improved MRI methods to quantify retinal and choroidal blood flow detect decreased blood flow in a model of glaucoma. Carolina Digital Repository (University of North Carolina at Chapel Hill). 2024. doi:10.17615/40pd-x688

BibTeX
@article{Chernoff2024,
  author = {Chernoff, Diane and Honkanen, Robert and Galenchik-Chan, Andre and Duong, Timothy Q. and JIANG, Zhao Hui and Muir, Eric R. and Tomorri, David},
  title = {Improved MRI methods to quantify retinal and choroidal blood flow detect decreased blood flow in a model of glaucoma},
  journal = {Carolina Digital Repository (University of North Carolina at Chapel Hill)},
  year = {2024},
  doi = {10.17615/40pd-x688}
}
Kostenlos starten →