Efficiency Evaluation of a DC Generator Using Experimental Loss Measurements

Elysa Nensy Irawan, Chisaki Osumi

Journal of Mechatronics and Artificial Intelligence · 30.06.2026 · 3 (1) · 57-70

DOI: 10.17509/jmai.v3i1.142 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Mechatronics and Artificial Intelligence, online erschienen am 30.06.2026. Verfasst von Elysa Nensy Irawan und 1 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY-SA 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This study evaluates the efficiency of a DC generator using experimental loss measurements based on a two-identical-machine method. Two identical DC machines were mechanically coupled, with one machine operated as the driving motor and the other as the generator under test. The total loss was determined from the difference between the motor input power and the generator output power, while the copper loss was calculated using the armature resistance obtained from a locked-rotor test. Since the generator did not have a field winding, only armature copper loss was considered. The friction loss was estimated from the no-load test, and the iron loss was determined using a residual loss method. The experimental results showed that the generator output power increased from 0.0064 W at 1.5 V to 1.8032 W at 5.0 V. The generator efficiency also increased with operating voltage, reaching a maximum value of 63.96% at 5.0 V. Copper loss increased significantly with load current and became a dominant loss component at higher operating conditions. The residual iron loss showed positive values at low voltage levels but became negative at higher voltages, indicating limitations in separating friction and iron losses using the current method. Overall, the proposed experimental approach was effective for evaluating the efficiency trend and identifying the dominant loss behavior of the DC generator, although further refinement is required to separate mechanical and magnetic losses more accurately.

Zitieren

APA

Irawan, E. N., & Osumi, C. (2026). Efficiency Evaluation of a DC Generator Using Experimental Loss Measurements. Journal of Mechatronics and Artificial Intelligence, 3(1), 57-70. https://doi.org/10.17509/jmai.v3i1.142

Vancouver

Irawan EN, Osumi C. Efficiency Evaluation of a DC Generator Using Experimental Loss Measurements. Journal of Mechatronics and Artificial Intelligence. 2026;3(1):57-70. doi:10.17509/jmai.v3i1.142

BibTeX
@article{Irawan2026,
  author = {Irawan, Elysa Nensy and Osumi, Chisaki},
  title = {Efficiency Evaluation of a DC Generator Using Experimental Loss Measurements},
  journal = {Journal of Mechatronics and Artificial Intelligence},
  year = {2026},
  volume = {3},
  number = {1},
  pages = {57--70},
  doi = {10.17509/jmai.v3i1.142}
}
Kostenlos starten →