A Robust Pre-processing Pipeline for Dermoscopic Skin Lesion Images Using Canny-Based Hair Removal and Adaptive Enhancement
Indian Journal Of Science And Technology · 11.06.2026 · 19 (20) · 1373-1383
DOI: 10.17485/ijst/v19i20.314 ↗Kurz gefasst
Fachartikel in der Zeitschrift Indian Journal Of Science And Technology, online erschienen am 11.06.2026. Verfasst von S Divya und 1 weiteren Autor:innen.
Abstract (Originalsprache)
Objectives
To present a viable preprocessing pipeline of dermoscopic images to maximize lesion appearance and minimise noise and artifacts to help in the diagnosis of skin cancer.
Method
The 7-step Skin Cancer Image Pre-Processing (SCIP) pipeline has been created and tested on three benchmark dermoscopic databases, i.e., ISIC, PH2, and HAM10000, with over 11,000 images. The image preprocessing steps are image resizing, hair removal, artifact removal with the DullRazor algorithm that uses Canny edge detection and Telea inpainting, Gray World based color normalization, contrast enhancement through Contrast Limited Adaptive Histogram Equalization (CLAHE), noise reduction with a median filter, and Min-Max normalization to fit a deep learning model.
Findings
As it was experimentally demonstrated, the proposed SCIP pipeline significantly enhanced lesion boundaries by approximately 27%. Additionally, it improved the contrast-to-noise ratio by 32% and reduced artifacts by more than 90%, the contrast-to-noise ratio by 32 percent and diminished the interference of hair and artifacts by more than 90 percent with respect to the raw dermoscopic images. Color normalization minimized variation in illumination across datasets by around 24 percent whereas median filter minimized the level of background noise by 18 percent with no impact on lesion structures. The pipeline reduced the classification error of deep learning models by 6.8%, 5.4%, and 4.9% on ISIC, HAM10000, and PH2 datasets, respectively, compared to standard preprocessing techniques. These findings indicate that the suggested method improves feature selection and facilitates quicker model convergence of automated skin cancer detection. Novelty: The proposed Skin Cancer Image Pre-Processing (SCIP) pipeline introduces a unified and adaptive preprocessing framework that integrates multiple complementary techniques, including Canny-based DullRazor hair removal, Gray World color normalization, CLAHE-based contrast enhancement, and median filtering, into a single standardized workflow. Unlike existing approaches that address individual preprocessing challenges in isolation, the SCIP framework simultaneously handles multiple artifacts while preserving lesion structure and ensuring cross-dataset consistency. The novelty lies in its system-level integration, cross-dataset evaluation, and quantitative validation demonstrating improved structural preservation, noise reduction, and artifact minimization across heterogeneous dermoscopic datasets. Keywords: Skin cancer, Image preprocessing, CLAHE, DullRazor, Normalization
Zitieren
APA
Divya, S., & Thilagavathi, S. (2026). A Robust Pre-processing Pipeline for Dermoscopic Skin Lesion Images Using Canny-Based Hair Removal and Adaptive Enhancement. Indian Journal Of Science And Technology, 19(20), 1373-1383. https://doi.org/10.17485/ijst/v19i20.314
Vancouver
Divya S, Thilagavathi S. A Robust Pre-processing Pipeline for Dermoscopic Skin Lesion Images Using Canny-Based Hair Removal and Adaptive Enhancement. Indian Journal Of Science And Technology. 2026;19(20):1373-1383. doi:10.17485/ijst/v19i20.314
BibTeX
@article{Divya2026,
author = {Divya, S and Thilagavathi, S},
title = {A Robust Pre-processing Pipeline for Dermoscopic Skin Lesion Images Using Canny-Based Hair Removal and Adaptive Enhancement},
journal = {Indian Journal Of Science And Technology},
year = {2026},
volume = {19},
number = {20},
pages = {1373--1383},
doi = {10.17485/ijst/v19i20.314}
}
EUVIMED