EUVIMEDEUVIMED entdecken
Crossref

Measurement of Cellular ATP Efflux by Establishment of Biosensor Cells

Min-Jeong Son, Qui Ahn Le, Joon-Chul Kim, Kyoung-Hee Kim, Sun-Hee Woo

Yakhak Hoeji · 30.01.2019 · 63 (1) · 30-36

DOI: 10.17480/psk.2019.63.1.30 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Yakhak Hoeji, online erschienen am 30.01.2019. Verfasst von Min-Jeong Son und 4 weiteren Autor:innen. Die Arbeit wurde bisher 1-mal zitiert (Crossref).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

In this study, we established a biosensor cell that can directly respond to ATP in order to measure ATP release from a single cell in real-time with high time resolution. We made HEK293 cells overexpressing P2X7 purinoceptors, the ATP-gated cation channel, with green fluorescence proteins (GFPs). Overexpression of P2X7 receptors was confirmed by reverse transcription-polymerase chain reaction, immunoblotting method, and fluorescence microscopy. In addition, the overexpression of P2X7 receptors was functionally confirmed by measuring ATP-induced cation current in these cells using whole-cell patch clamp technique. Application of ATP-containing external solutions produced inward currents at −70 mV in P2X7-expressing HEK293 cells, in a concentration-dependent manner with an EC50 of 31.2 μM. Maximal P2X7 inward current (14.2 ± 1.76 pA/pF, n = 10) was observed at about 0.8 mM ATP. ATP-dependent HEK293 cell currents were almost completely blocked by suramin (30 μM), the P2 purinergic antagonist (0.17 ± 0.13 pA/pF, n = 10, p < 0.0001), and they were negligible in the HEK293 cells expressing GFP only (0.28 ± 0.07 pA/pF, n = 11). The ATP-biosensor cells successfully detected ATP release from single atrial myocyte under shear stress at millisecond intervals. This ATP detection method may be used to directly quantify real-time ATP release, which may provide improved spatial and temporal information on cellular ATP release.

Zitieren

APA

Son, M., Le, Q. A., Kim, J., Kim, K., & Woo, S. (2019). Measurement of Cellular ATP Efflux by Establishment of Biosensor Cells. Yakhak Hoeji, 63(1), 30-36. https://doi.org/10.17480/psk.2019.63.1.30

Vancouver

Son M, Le QA, Kim J, Kim K, Woo S. Measurement of Cellular ATP Efflux by Establishment of Biosensor Cells. Yakhak Hoeji. 2019;63(1):30-36. doi:10.17480/psk.2019.63.1.30

BibTeX
@article{Son2019,
  author = {Son, Min-Jeong and Le, Qui Ahn and Kim, Joon-Chul and Kim, Kyoung-Hee and Woo, Sun-Hee},
  title = {Measurement of Cellular ATP Efflux by Establishment of Biosensor Cells},
  journal = {Yakhak Hoeji},
  year = {2019},
  volume = {63},
  number = {1},
  pages = {30--36},
  doi = {10.17480/psk.2019.63.1.30}
}
Kostenlos starten →