Advanced volar locking plate fixation for intra and extra articular distal radius fractures: a retrospective study
Medicinski Glasnik · 2026
DOI: 10.17392/2047-23-01 ↗Kurz gefasst
Fachartikel in der Zeitschrift Medicinski Glasnik, 2026. Verfasst von Giuseppe Rovere und 11 weiteren Autor:innen. Beteiligte Einrichtung: Policlinico Tor Vergata, Rome. Hauptthemen laut MEDLINE: Bone Plates, Radius Fractures, Fracture Fixation, Internal, Wrist Fractures. Die Arbeit wurde bisher 1-mal zitiert (Crossref). Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).
Abstract (Originalsprache)
<p style="font-size: medium; color: #000000; font-weight: 400;"><strong>Background</strong></p> <p style="font-size: medium; color: #000000; font-weight: 400;">Distal radius fractures are among the most common orthopedic injuries, posing significant challenges due to their high prevalence and potential for long-term functional impairment. Volar locking plates have emerged as the gold standard for managing unstable and extra-articular fractures, offering superior outcomes compared to traditional methods. This study evaluates the clinical, radiographic, and functional outcomes of volar locking plate fixation in 34 patients with intra and extra-articular distal radius fractures.</p> <p style="font-size: medium; color: #000000; font-weight: 400;"><strong>Methods</strong></p> <p style="font-size: medium; color: #000000; font-weight: 400;">This retrospective study analyzed 34 patients treated for intra and extra-articular distal radius fractures with volar locking plates at a single orthopedic center. Patients were followed for a mean duration of 24 months (range: 12–36 months).</p> <p style="font-size: medium; color: #000000; font-weight: 400;">Outcomes were assessed using the Disabilities of the Arm, Shoulder, and Hand (DASH) score, Visual Analog Scale (VAS) for pain, range of motion (ROM), and radiographic parameters. Complications, including hardware-related issues and soft tissue irritation, were recorded. Statistical analysis compared preoperative and postoperative outcomes, with significance set at p < 0.05.</p> <p style="font-size: medium; color: #000000; font-weight: 400;"><strong>Results</strong></p> <p style="font-size: medium; color: #000000; font-weight: 400;">The mean DASH score at the final follow-up was 4.2 ± 1.8, reflecting excellent functional recovery. Pain relief was complete, with all patients reporting a VAS score of 0. ROM restoration was highly satisfactory, achieving 93–98% of contralateral wrist motion. Radiographic evaluations confirmed 100% fracture consolidation with no cases of malunion or nonunion. Complications were minimal, with only two patients experiencing transient soft tissue discomfort, managed conservatively. No tendon irritation or hardware-related complications were observed.</p> <p style="font-size: medium; color: #000000; font-weight: 400;"><strong>Conclusions</strong></p> <p style="font-size: medium; color: #000000; font-weight: 400;">Volar locking plate fixation for intra and extra-articular distal radius fractures demonstrated excellent clinical, functional, and radiographic outcomes in this cohort of 34 patients. The low-profile design and anatomical contouring of modern plates minimized complications while promoting effective pain relief and rapid functional recovery.</p>
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Policlinico Tor Vergata, Rome.
- Department of Precision Medicine in Medical, Surgical and Critical Care (Me.Pre.C.C.), University of Palermo, Palermo, Italy.
- Orthopaedic and Traumatology Department, S. Spirito Hospital, Lungotevere in Sassia 1, 00193, Rome, Italy.
- Department of Orthopedics and Trauma Surgery, Fondazione Casa Sollievo Della Sofferenza IRCCS, 71013, San Giovanni Rotondo, Italy.
- Department of Orthopaedics and Traumatology, Ospedale San Giovanni Bosco di Torino - ASL Città di Torino, Turin, Italy.
- Department of Clinical Science and Translational Medicine, Section of Orthopaedics and Traumatology, University of Rome "Tor Vergata", Rome, Italy.
Zitieren
APA
Rovere, G., Bosco, F., Vigni, G., Sinno, E., Perna, A., Giustra, F., Liuzza, F., Smakaj, A., De Maio, F., Ziranu, A., Tulumello, G., & Camarda, L. (2026). Advanced volar locking plate fixation for intra and extra articular distal radius fractures: a retrospective study. Medicinski Glasnik. https://doi.org/10.17392/2047-23-01
Vancouver
Rovere G, Bosco F, Vigni G, Sinno E, Perna A, Giustra F, et al. Advanced volar locking plate fixation for intra and extra articular distal radius fractures: a retrospective study. Medicinski Glasnik. 2026. doi:10.17392/2047-23-01
BibTeX
@article{Rovere2026,
author = {Rovere, Giuseppe and Bosco, Francesco and Vigni, Giulio and Sinno, Ennio and Perna, Andrea and Giustra, Fortunato and Liuzza, Francesco and Smakaj, Amarildo and De Maio, Fernando and Ziranu, Antonio and Tulumello, Giuseppe and Camarda, Lawrence},
title = {Advanced volar locking plate fixation for intra and extra articular distal radius fractures: a retrospective study},
journal = {Medicinski Glasnik},
year = {2026},
doi = {10.17392/2047-23-01}
}
EUVIMED