Comparison of Effects of Flutter Device versus Autogenic Drainage on Peak Expiratory Flow Rate, Oxygen Saturation, Respiratory Rate and Pulse Rate in COPD Patients
Journal of Novel Physiotherapy and Physical Rehabilitation · 2015
DOI: 10.17352/2455-5487.000024 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Novel Physiotherapy and Physical Rehabilitation, 2015. Verfasst von L Kumar. Die Arbeit nennt 10 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).
Themen: COPD
Abstract (Originalsprache)
Purpose
To evaluate the effects of short term treatment of Flutter device and Autogenic Drainage (AD) in patients with chronic obstructive pulmonary disease (COPD).
Methods
Thirty male and female COPD patients were randomly assigned into two groups, were trained for the intervention, and then the intervention was performed by them.Peak expiratory flow rate (PEFR), Arterial Oxygen saturation (SpO 2 ), Respiratory rate and Pulse rate were measured pre and post.
Results
There was no statistically significant difference between the groups.Within group analysis showed that both the treatments were equally effective in improving the dependent variables. Conclusion:Flutter is as effective as the AD.Any of the techniques can be used in COPD patients according to patients and physiotherapist preferences.smaller airways by breathing in the base of your lungs, "Collecting" the mucus from the middle airways by breathing at low to mid lung levels, "Evacuating" the mucus from the central airways by breathing at mid to high lung levels [4].In an earlier comparative study reported between Flutter device and Autogenic Drainage, Skaria et al. [5], found that Flutter device is more effective than the forced expiratory technique i.e.Autogenic Drainage.They reported greater improvement in terms of oxygen saturation and peak expiratory flow rate in the patients of moderate chronic bronchitis, who had used Flutter device.Ernst et al. [6], also did a comparative study between Flutter and AD but on patients of cystic fibrosis.They reported that oscillations applied by Flutter are better capable of decreasing mucus viscoelasticity within the airways as compared to the Autogenic drainage.Different airway clearance techniques were used for the comparison with the Flutter, which showed inconsistencies in its application, and various outcome measures all contribute to the difficulties in interpreting the literature.We could not find any comparative study of the flutter device and Autogenic drainage in patients with COPD.Thus, the aim of this study was to compare the effectiveness of Flutter device and Autogenic Drainage in COPD patients.
Zitieren
APA
Kumar, L. (2015). Comparison of Effects of Flutter Device versus Autogenic Drainage on Peak Expiratory Flow Rate, Oxygen Saturation, Respiratory Rate and Pulse Rate in COPD Patients. Journal of Novel Physiotherapy and Physical Rehabilitation. https://doi.org/10.17352/2455-5487.000024
Vancouver
Kumar L. Comparison of Effects of Flutter Device versus Autogenic Drainage on Peak Expiratory Flow Rate, Oxygen Saturation, Respiratory Rate and Pulse Rate in COPD Patients. Journal of Novel Physiotherapy and Physical Rehabilitation. 2015. doi:10.17352/2455-5487.000024
BibTeX
@article{Kumar2015,
author = {Kumar, L},
title = {Comparison of Effects of Flutter Device versus Autogenic Drainage on Peak Expiratory Flow Rate, Oxygen Saturation, Respiratory Rate and Pulse Rate in COPD Patients},
journal = {Journal of Novel Physiotherapy and Physical Rehabilitation},
year = {2015},
doi = {10.17352/2455-5487.000024}
}
EUVIMED